Novel preclinical PET geometrical concept using a monolithic scintillator crystal offering concurrent enhancement in spatial resolution and detection sensitivity: a simulation study

Abstract: We propose a small-animal PET scanner design combining two sets of monolithic crystals with two different thicknesses. The detectors with thinner crystals serve for high resolution imaging while the thicker crystals retain the detection efficiency. Two small-animal PET models based on 10 and 12 detector blocks made of monolithic LYSO crystals were implemented in the GEANT4 Monte Carlo toolkit. In each of these models, half of the detector blocks consisted of a crystal thickness of 10 mm whereas the second half… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
11
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 24 publications
(12 citation statements)
references
References 38 publications
1
11
0
Order By: Relevance
“…5). Similar low numbers of scatter and randoms have previously been noted on other monolithic crystal detection systems, which also investigated a reduction in the number of blocks to their coincidence detection system [38]. Typical injected activities for PET studies are in the range of 200-1000 MBq; however, by the activity concentration reaching, the radial and ulnar arteries are more likely in the range of < 500 kBq/ml.…”
Section: Discussionsupporting
confidence: 66%
“…5). Similar low numbers of scatter and randoms have previously been noted on other monolithic crystal detection systems, which also investigated a reduction in the number of blocks to their coincidence detection system [38]. Typical injected activities for PET studies are in the range of 200-1000 MBq; however, by the activity concentration reaching, the radial and ulnar arteries are more likely in the range of < 500 kBq/ml.…”
Section: Discussionsupporting
confidence: 66%
“…The required GEANT4 libraries for electron interactions, ionization photons, and optical photon interactions were added to the simulation physics list [18,19]. Further details about the validation process are provided in [20,21].…”
Section: Monte Carlo Simulationsmentioning
confidence: 99%
“…The validation of our proposed detector/scanner simulation and image reconstruction algorithm was performed through comparison with the experimental measurements acquired on the Xtrim preclinical PET scanner. The details of the validation procedure were described in previous studies [20,21,23]. Table 1 summarizes the technical features of the simulated Xtrim-PET.…”
Section: Validation and Performance Evaluationmentioning
confidence: 99%
“…With the help of medical imaging, it is possible to detect and diagnose a variety of diseases, and thereby the healthcare industry is seeking innovations in the imaging field [105][106][107][108]. Up to now, NDs fabricated by explosives have not been considered as promising materials for NVcenter-based imaging applications.…”
Section: Fluorescencementioning