2019
DOI: 10.1007/s00253-019-09699-x
|View full text |Cite
|
Sign up to set email alerts
|

Novel polymeric dressing to the treatment of infected chronic wound

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0
1

Year Published

2020
2020
2021
2021

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 28 publications
(15 citation statements)
references
References 58 publications
0
14
0
1
Order By: Relevance
“…Thus, although the grafted matrices had a higher drug content compared to the non‐grafted matrices, NRL‐ g ‐AAc and PCL‐ g ‐AAc release SBB in a shorter period than NRL‐ ng and PCL‐ ng , respectively. The drug release of all matrices obeys bi‐exponential first‐order release which is commonly observed for drug/natural product release from NRL 13,43 . The bi‐exponential first‐order release is described by Equation ) and the values of each parameter and the determination coefficient ( R 2 ) are listed in Table 2.…”
Section: Results and Discusionmentioning
confidence: 96%
See 1 more Smart Citation
“…Thus, although the grafted matrices had a higher drug content compared to the non‐grafted matrices, NRL‐ g ‐AAc and PCL‐ g ‐AAc release SBB in a shorter period than NRL‐ ng and PCL‐ ng , respectively. The drug release of all matrices obeys bi‐exponential first‐order release which is commonly observed for drug/natural product release from NRL 13,43 . The bi‐exponential first‐order release is described by Equation ) and the values of each parameter and the determination coefficient ( R 2 ) are listed in Table 2.…”
Section: Results and Discusionmentioning
confidence: 96%
“…PCL‐ g ‐AAc after PBS wash showed a band at 1,560 cm −1 , characteristic of the carboxylate (COO − ) from the acrylate 41,42 . The FTIR spectrum of NRL‐ ng is displayed in Figure 2 and shows the characteristic bands at 836 cm −1 (cis‐1,4‐isoprene) and at 2,970 cm −1 , representing the ‐CH stretch 43,44 . The FTIR spectrum of NRL‐ g ‐AAc presented a band at 1,706 cm −1 (carboxylic acid) and a broad band in the range of 2,000–3,600 cm −1 (COOH), indicating successful grafting.…”
Section: Results and Discusionmentioning
confidence: 99%
“…Various Gram-positive, Gram-negative, aerobic, and anaerobic bacteria as well as different species of fungi have been isolated from skin infections [17,20]. The most common bacterial pathogens implicated in wound infections include Staphylococcus aureus, Enterococcus spp., Streptococcus pyogenes, Escherichia coli, and Pseudomonas aeruginosa [15,21,22]. Other bacteria include Klebsiella pneumoniae, Acinetobacter spp., and Enterobacter spp.…”
Section: Bacterial Infection Of Woundsmentioning
confidence: 99%
“…Thus, it was observed that standard L929 cells did not differ from the ASDC isolated in this study. The prospects of performing autologous ADSCs grafts in burns associated with the topical use of a potent antimicrobial, anti-inflammatory and regenerating agent based on RP extracts 79 could be advantageous with occlusive dressings with natural latex rubber 46,80 .…”
Section: Indirect Mtt Cytotoxic Assaysmentioning
confidence: 99%