2001
DOI: 10.1016/s1367-5931(00)00184-8
|View full text |Cite
|
Sign up to set email alerts
|

Novel methods for biocatalyst screening

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
54
0

Year Published

2001
2001
2017
2017

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 155 publications
(54 citation statements)
references
References 49 publications
0
54
0
Order By: Relevance
“…The absorbance is dependent on both [G] t and ee because the right chamber is occupied by the chiral host (S,S)-2 [Eq. (2)]. Putting these two equations together, the values of [G] t and ee can be solved.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The absorbance is dependent on both [G] t and ee because the right chamber is occupied by the chiral host (S,S)-2 [Eq. (2)]. Putting these two equations together, the values of [G] t and ee can be solved.…”
Section: Resultsmentioning
confidence: 99%
“…Such a signal is related to [G] t and ee by way of a mathematical function of solution equilibrium constants and molar absorptivities ([Equation (2)], Scheme 1). [11] Because [G] t is known from the measurement using the achiral host H, the ee of the sample can be obtained by solving Equation (2). We have used an arylboronic acid based eIDA to quantitatively analyze chiral a-hydroxycarboxylates and diols.…”
Section: Introductionmentioning
confidence: 99%
“…This may also occur when abzymes are obtained as idiotypic or anti-idiotypic antibodies against the enzyme, as observed for AChE-like antibodies. [33][34][35][36] These were the reasons why we changed the experimental approach to the isolation of an AchE-like scFv, integrating the screening by genetic selection 37,38 with the bait-and-switch strategy 39,40 for the elicitation of antibody catalysts. Phage libraries represent an excellent tool for antibody selection as demonstrated by the drugs already produced on the market.…”
Section: Discussionmentioning
confidence: 99%
“…In general, these techniques have a limited dynamic (concentration) range. In addition, UV-Vis and fluorescence spectroscopies require an optical activity of the reactants or products and, in their absence, the analysis is more complicated as chromogenic and fluorogenic substrates are needed [8][9][10]. Therefore, discontinuous methods are widely used for the monitoring of chemical reactions, including chromatography, mass spectrometry (MS) and capillary electrophoresis [9].…”
Section: Introductionmentioning
confidence: 99%