2015
DOI: 10.1007/s10439-015-1499-9
|View full text |Cite
|
Sign up to set email alerts
|

Novel Method to Track Soft Tissue Deformation by Micro-Computed Tomography: Application to the Mitral Valve

Abstract: Increasing availability of micro-computed tomography (μCT) as a structural imaging gold-standard is bringing unprecedented geometric detail to soft tissue modeling. However, the utility of these advances is severely hindered without analogous enhancement to the associated kinematic detail. To this end, labeling and following discrete points on a tissue across various deformation states is a well-established approach. Still, existing techniques suffer limitations when applied to complex geometries and large def… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
3
3

Relationship

1
5

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 29 publications
0
10
0
Order By: Relevance
“…20 Strain in the belly region was found to be 47.1±21.5% (n = 61 markers). This agrees well with previous in vitro studies by Jimenez et al (36±14%) 15 , He et al (42±20%) 12 , and Sacks et al (47±10%) 24 .…”
Section: Resultsmentioning
confidence: 92%
See 2 more Smart Citations
“…20 Strain in the belly region was found to be 47.1±21.5% (n = 61 markers). This agrees well with previous in vitro studies by Jimenez et al (36±14%) 15 , He et al (42±20%) 12 , and Sacks et al (47±10%) 24 .…”
Section: Resultsmentioning
confidence: 92%
“…Following the finite element simulation of MV closure, the accuracy of the systolic MV geometry can be directly compared to the experimental results using discrete marker positions from the microCT scans. Additionally, the fiducial markers can be used to measure directional strain in response to both levels of loading 20 , and fine-tune the material properties of the FE model.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Methodologies for in vitro MV imaging, image processing, and FE mesh generation have been described previously in detail . Briefly, three freshly excised ovine MV specimens were sutured to an adjustable annulus holder by a ford interlocking stitch and mounted into an extensively validated cylindrical left heart simulator . Prior to imaging, the leaflets were instrumented with approximately 100 high‐contrast fiducial markers uniformly distributed over the entire leaflet surface (Figure ), and the papillary muscles were attached to adjustable rods.…”
Section: Methodsmentioning
confidence: 99%
“…[55][56][57][58][59][60] Briefly, three freshly excised ovine MV specimens were sutured to an adjustable annulus holder by a ford interlocking stitch and mounted into an extensively validated cylindrical left heart simulator. 41,[61][62][63] Prior to imaging, the leaflets were instrumented with approximately 100 high-contrast fiducial markers uniformly distributed over the entire leaflet surface ( Figure 2), and the papillary muscles were attached to adjustable rods. The system was then installed into a pulsatile flow loop for hemodynamic tuning to match the parameters of healthy left ventricular function, and the positions of the papillary muscles were adjusted to achieve normal coaptation behavior.…”
Section: Data Collection and Processing 221 In Vitromentioning
confidence: 99%