“…An analysis of the works [10][11][12][13][14][15][16][17][18][19] showed that the most often used in the RP simulation are third-order Chebyshev and Butterworth low-pass filters (LPFs). In [22], a mathematical model of the MP containing the third-order Butterworth LPF was studied, and in the framework of this work, the third-order Chebyshev LPF is considered. The mathematical model in the form of a transfer function (TF) for the MP 'CT↔active auxiliary CT↔Chebyshev third-order low-pass filter' has the following general form (1).…”