2012
DOI: 10.1016/j.ijpharm.2012.07.031
|View full text |Cite
|
Sign up to set email alerts
|

Novel lipid based oral formulation of curcumin: Development and optimization by design of experiments approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
26
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 55 publications
(28 citation statements)
references
References 15 publications
1
26
0
Order By: Relevance
“…intrinsic permeability, effective permeability and wall permeability, the OPT S-SNEDDS exhibited nearly 53, 52 and 227% increase, followed by the inclusion complex showing nearly 21, 9 and 30% rise, whereas in case of the MKT formulation, only 14, 7 and 21% enhancement was observed as compare to the pure drug. This confirmed significant improvement in permeability parameters of OPT S-SNEDDS, especially in wall permeability, ostensibly ascribed to the synergistic effect of lipid and emulgent present in the formulation (Pawar et al, 2012).…”
Section: In Situ Intestinal Perfusion Studiessupporting
confidence: 64%
“…intrinsic permeability, effective permeability and wall permeability, the OPT S-SNEDDS exhibited nearly 53, 52 and 227% increase, followed by the inclusion complex showing nearly 21, 9 and 30% rise, whereas in case of the MKT formulation, only 14, 7 and 21% enhancement was observed as compare to the pure drug. This confirmed significant improvement in permeability parameters of OPT S-SNEDDS, especially in wall permeability, ostensibly ascribed to the synergistic effect of lipid and emulgent present in the formulation (Pawar et al, 2012).…”
Section: In Situ Intestinal Perfusion Studiessupporting
confidence: 64%
“…CRM concentrations in the brain homogenate were determined using the HPLC system as reported by Pawar et al (2012). The drug concentration in plasma was analyzed by a high-performance liquid chromatography (HPLC) method using the Rheodine type manual injector.…”
Section: Chromatographic Conditionsmentioning
confidence: 99%
“…The multidimensional combination and interaction of independent variables and process parameters, that have been confirmed to offer assurance of quality, is term as the design space [3,33]. Design space may possibly be determined from the common region of doing well operational range designed for the two responses.…”
Section: Experimental Validation Of Design Spacementioning
confidence: 99%