Cpem 2010 2010
DOI: 10.1109/cpem.2010.5544520
|View full text |Cite
|
Sign up to set email alerts
|

Novel frequency measurement method with low sampling time

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…There are a few solutions for determining instantaneous frequency of a power signal. Among the most popular are the interpolated DFT, sine fitting, Hilbert transform (Mostarac et al, 2010), and zoom-DFT. In the case of zoom-DFT, the chirp z-transform is often used for decreasing the time of computation (Huang et al, 2007;Mostarac et al, 2010).…”
Section: Modulation Of Instantaneous Frequency Voltage Fundamental Components and Chosen Harmonics Research Methodologymentioning
confidence: 99%
See 1 more Smart Citation
“…There are a few solutions for determining instantaneous frequency of a power signal. Among the most popular are the interpolated DFT, sine fitting, Hilbert transform (Mostarac et al, 2010), and zoom-DFT. In the case of zoom-DFT, the chirp z-transform is often used for decreasing the time of computation (Huang et al, 2007;Mostarac et al, 2010).…”
Section: Modulation Of Instantaneous Frequency Voltage Fundamental Components and Chosen Harmonics Research Methodologymentioning
confidence: 99%
“…Among the most popular are the interpolated DFT, sine fitting, Hilbert transform (Mostarac et al, 2010), and zoom-DFT. In the case of zoom-DFT, the chirp z-transform is often used for decreasing the time of computation (Huang et al, 2007;Mostarac et al, 2010). Moreover, the comparative study on the application of the zoom-DFT and the Hilbert-Huang transform (HHT) for instantaneous frequency identification in maritime microgrids revealed that the obtained results were fully comparable and the conclusions resulting from both studies were the same (Tarasiuk et al, 2020).…”
Section: Modulation Of Instantaneous Frequency Voltage Fundamental Components and Chosen Harmonics Research Methodologymentioning
confidence: 99%
“…For measurement of sampled signal phase and frequency both methods use built in functions like Extract single tone information that analyzes whole sampled signal to achieve the best result. Signal phase and frequency can be also measured with other algorithms [6,7]. This step is very important because accuracy of both methods depends on the accuracy of the signal phase and frequency measurement.…”
Section: A Realization Of Methods In Ni Labviewmentioning
confidence: 99%