2021
DOI: 10.3390/molecules26051402
|View full text |Cite
|
Sign up to set email alerts
|

Novel Fast Chromatography-Tandem Mass Spectrometric Quantitative Approach for the Determination of Plant-Extracted Phytosterols and Tocopherols

Abstract: Phytosterols and tocopherols are commonly used in food and pharmaceutical industries for their health benefits. Current analysis methods rely on conventional liquid chromatography, using an analytical column, which can be tedious and time consuming. However, simple, and fast analytical methods can facilitate their qualitative and quantitative analysis. In this study, a fast chromatography-tandem mass spectrometric (FC-MS/MS) method was developed and validated for the quantitative analysis of phytosterols and t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
16
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(18 citation statements)
references
References 57 publications
(24 reference statements)
2
16
0
Order By: Relevance
“…The resulting mixture was chilled for 1 h. During the chilling process, PS crystallized and was collected by vacuum filtration. The PS was composed of brassicasterol, campesterol, and β-sitosterol (Table ), and the purity of the extract was >90% as determined by our previously developed LC-MS/MS method . In brief, 1 mg/mL PS extract was prepared in chloroform and was analyzed in LC-MS/MS using freshly prepared calibration and quality control standards .…”
Section: Materials and Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The resulting mixture was chilled for 1 h. During the chilling process, PS crystallized and was collected by vacuum filtration. The PS was composed of brassicasterol, campesterol, and β-sitosterol (Table ), and the purity of the extract was >90% as determined by our previously developed LC-MS/MS method . In brief, 1 mg/mL PS extract was prepared in chloroform and was analyzed in LC-MS/MS using freshly prepared calibration and quality control standards .…”
Section: Materials and Methodsmentioning
confidence: 99%
“…The PS was composed of brassicasterol, campesterol, and β-sitosterol (Table ), and the purity of the extract was >90% as determined by our previously developed LC-MS/MS method . In brief, 1 mg/mL PS extract was prepared in chloroform and was analyzed in LC-MS/MS using freshly prepared calibration and quality control standards . The development of the liposomal PS was reported in our published work, which showed a 90% entrapment efficacy. , In brief, the PS was formulated into liposomes composed of PC and tocopherols.…”
Section: Materials and Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, simultaneous introduction of numerous compounds into the ion-source results in abundant matrix effects leading to sensitivity loss [ 2 ]. Recently, dilute-and-shoot methods [ 3 ] and the use of a short or guard column in the FIA-MS method (i.e., fast chromatography) [ 4 ] have been developed to overcome this effect.…”
Section: Introductionmentioning
confidence: 99%
“…Several analytical protocols have been proposed in the literature for tocopherol analysis, employing high-pressure liquid chromatography coupled to diode array (HPLC-DAD) [ 27 , 28 , 29 ], UV–Vis [ 30 , 31 ], fluorescence (FLD) [ 32 ], or mass spectrometric (MS) detectors [ 33 , 34 , 35 , 36 ]. Undoubtedly, UV detectors allow a fast, reliable, and cost-effective analysis, especially when it comes to such a small number of compounds, where separation and identification can be achieved without much adversity.…”
Section: Introductionmentioning
confidence: 99%