Novel electrochemical sensing platform based on a nanocomposite of PVA/PVP/RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation

Abstract: This article describes the development of a new electrochemical platform composed by a polymer mixture and graphene oxide (GO). The working electrode of a screen-printed carbon electrode (SPCE) was modified with nanocomposite constituted by poly-vinyl alcohol (PVA), poly-vinylpyrrolidone (PVP) and GO, which was electrochemically reduced to obtain PVA/PVP/RGO/SPCE. The interactions and morphology of the PVA/PVP/GO nanocomposite were investigated by SEM, FTIR and UV-Vis. SEM images indicated an excellent dispers… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(6 citation statements)
references
References 41 publications
(37 reference statements)
1
5
0
Order By: Relevance
“…The presence of peaks at 2249 cm –1 (CN stretching), 1095 cm –1 (C–O–C stretching), and the greatly reduced intensity of the peak at 3400 cm –1 (O–H stretching) clearly reveal that partial transformation of −OH to −OCH 2 CH 2 CN occurred during the cyanoethylation of PVA and formed PVA–CN accordingly. Furthermore, in comparison with the spectrum of PVA–CN, the characteristic peak at 1258 cm –1 (C–OH stretching) is not observed in the PVA–CN–SO 3 spectrum . In addition, the PVA–CN–SO 3 spectrum also shows new bands at 1173, 1046, and 926 cm –1 , corresponding to S=O asymmetric, S=O symmetric, and C–S stretching, respectively. , Thus, these results provide supporting evidence for the successful formation of PVA–CN–SO 3 .…”
Section: Resultssupporting
confidence: 52%
See 1 more Smart Citation
“…The presence of peaks at 2249 cm –1 (CN stretching), 1095 cm –1 (C–O–C stretching), and the greatly reduced intensity of the peak at 3400 cm –1 (O–H stretching) clearly reveal that partial transformation of −OH to −OCH 2 CH 2 CN occurred during the cyanoethylation of PVA and formed PVA–CN accordingly. Furthermore, in comparison with the spectrum of PVA–CN, the characteristic peak at 1258 cm –1 (C–OH stretching) is not observed in the PVA–CN–SO 3 spectrum . In addition, the PVA–CN–SO 3 spectrum also shows new bands at 1173, 1046, and 926 cm –1 , corresponding to S=O asymmetric, S=O symmetric, and C–S stretching, respectively. , Thus, these results provide supporting evidence for the successful formation of PVA–CN–SO 3 .…”
Section: Resultssupporting
confidence: 52%
“…Furthermore, in comparison with the spectrum of PVA−CN, the characteristic peak at 1258 cm −1 (C−OH stretching) is not observed in the PVA−CN−SO 3 spectrum. 29 In addition, the PVA−CN−SO 3 spectrum also shows new bands at 1173, 1046, and 926 cm −1 , corresponding to S=O asymmetric, S=O symmetric, and C−S stretching, respectively. 30,31 Thus, these results provide supporting evidence for the successful formation of PVA−CN−SO 3 .…”
Section: Characterizations Of Pva−cn−so 3 Polymersmentioning
confidence: 98%
“…The presented probe showed a good potential towards the POC for T. gondii. Takara et al develop an electrochemical biosensing platform based on a nanocomposite of poly-vinyl alcohol/ poly-vinylpyrolidone and graphene oxide (PVA/PVP/RGO) for T. gondii diagnosis [71]. The LOD was 0.012 U/ml was reported with very less variation during intra-day and inter-day assays.…”
Section: Toxoplasmosismentioning
confidence: 99%
“…Although these measurement methods are able to achieve IL-6 detection to some extent, a variety of factors restrict further development, including complicated procedures requiring professional executors, low accuracy, time-consuming, and expensive instruments in the laboratory. The electrochemical immunoassay of specific antigen-antibody interactions has significant application in biomedical diagnostics ( Hou et al, 2019 ; Takara et al, 2019 ). Electrochemical immunosensors, which are designed to be based on biosensing technology, have many significant advantages over conventional detection methods, such as simple operation, convenient carrying, and high sensitivity ( Sun et al, 2020 ).…”
Section: Introductionmentioning
confidence: 99%