2016
DOI: 10.1080/00032719.2016.1167899
|View full text |Cite
|
Sign up to set email alerts
|

Novel Electrochemical Immunoassay for Carcinoembryonic Antigen Using Ferrocenyl Polymer Nanospheres

Abstract: A new electrochemical immunoassay based on a sandwich format was developed for carcino embryonie antige using ferrocenyl polymer nanospheres as the recognition elements. Ferrocenyl nanospheres were synthesized by coordination polymerization and characterized by transmission Downloaded by [University of California Santa Barbara] at 02:40 15 June 20163 electron microscopy, energy dispersive X-ray spectrometry, and infrared spectroscopy.Monoclonal carcino embryonie antibodies were immobilized on a nanogold-modifi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 33 publications
0
1
0
Order By: Relevance
“…The analytical characteristics of the developed immunosensor are not inferior to analogues, however, the proposed procedure for antibody immobilization compares favourably with simplicity and expressivity, and Au/L-Cysteine/AuNPs/ Ab 1 /Ag/FCP-Ab 2 DPV 0.01-50 0.04 [28] GCE/Ba-NH-AuNPs/Glu/Ab EIS 0.05-120 0.01 [29] NiCo PB nanocubes/Apt EIS 10 À 6 -0.5 7.4 · 10 À 7 [30] HGN-MWCNT/Apt DPV 10 À 6 -10 8.2 · 10 À 7 [31] SnS 2 -R/Apt 1 /CEA/ Apt 2 -Au@CuS-GR/4-CN PEC 10 À 4 -10 5.9 · 10 À 6 [32] Full Paper www.electroanalysis.wiley-vch.de address functionalization of the sensor surface by electrografting opens up wide prospects for miniaturization and creation of lab-on-the-chip devices.…”
Section: Optimization Of Immunoassay a Comparison Characterization Omentioning
confidence: 99%
“…The analytical characteristics of the developed immunosensor are not inferior to analogues, however, the proposed procedure for antibody immobilization compares favourably with simplicity and expressivity, and Au/L-Cysteine/AuNPs/ Ab 1 /Ag/FCP-Ab 2 DPV 0.01-50 0.04 [28] GCE/Ba-NH-AuNPs/Glu/Ab EIS 0.05-120 0.01 [29] NiCo PB nanocubes/Apt EIS 10 À 6 -0.5 7.4 · 10 À 7 [30] HGN-MWCNT/Apt DPV 10 À 6 -10 8.2 · 10 À 7 [31] SnS 2 -R/Apt 1 /CEA/ Apt 2 -Au@CuS-GR/4-CN PEC 10 À 4 -10 5.9 · 10 À 6 [32] Full Paper www.electroanalysis.wiley-vch.de address functionalization of the sensor surface by electrografting opens up wide prospects for miniaturization and creation of lab-on-the-chip devices.…”
Section: Optimization Of Immunoassay a Comparison Characterization Omentioning
confidence: 99%