1998
DOI: 10.1152/ajpheart.1998.274.4.h1218
|View full text |Cite
|
Sign up to set email alerts
|

Novel catheterization technique for the in vivo measurement of pulmonary vascular responses in rats

Abstract: A novel cardiac catheterization technique was devised to investigate the pulmonary arterial pressure-blood flow relationship in intact spontaneously breathing rats (ISBR) under physiological conditions with constant left atrial pressure and controlled blood flow within the normal range. Observations using this new technique in vivo were contrasted with data derived with isolated perfused rat lungs in vitro. Unlike results in in vitro isolated perfused rat lungs, the pressure-flow curves in vivo were curvilinea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
17
0

Year Published

1999
1999
2010
2010

Publication Types

Select...
8
1

Relationship

5
4

Authors

Journals

citations
Cited by 22 publications
(20 citation statements)
references
References 29 publications
3
17
0
Order By: Relevance
“…The pulmonary response to U-46619 can be inhibited with thromboxane receptor blocking agents and is not dependent on platelet aggregation or changes in bronchomotor tone, and this agent has greater effect on the pulmonary than systemic vascular bed (13,14,17,24,25). The observation that isradipine has substantial pulmonary vasodilator activity is consistent with studies showing that calcium entry blockers are useful in the treatment of the early phase of primary pulmonary hypertension (31).…”
Section: Discussionsupporting
confidence: 74%
See 1 more Smart Citation
“…The pulmonary response to U-46619 can be inhibited with thromboxane receptor blocking agents and is not dependent on platelet aggregation or changes in bronchomotor tone, and this agent has greater effect on the pulmonary than systemic vascular bed (13,14,17,24,25). The observation that isradipine has substantial pulmonary vasodilator activity is consistent with studies showing that calcium entry blockers are useful in the treatment of the early phase of primary pulmonary hypertension (31).…”
Section: Discussionsupporting
confidence: 74%
“…A femoral artery was catheterized with PE 50 tubing for the measurement of systemic arterial pressure, and the left jugular and femoral veins were catheterized with PE 50 tubing for intravenous injections or infusions of drugs and fluids. For measurement of pulmonary arterial pressure, a specially designed single lumen 3F catheter with a radio-opaque marker and curved tip was passed from the right jugular vein into the right ventricle and main pulmonary artery under fluoroscopic guidance (Picker Surveyor), as described previously (9,13). Pulmonary and systemic arterial pressures were measured with NAMIC Perceptor transducers (Boston Scientific), digitized by a BIOPAC MP100 data acquisition system, and stored on a Dell PC.…”
Section: Methodsmentioning
confidence: 99%
“…The left jugular and femoral veins were catheterized with PE50 tubing for iv administration and infusion of drugs and fluids. For measurement of pulmonary arterial pressure, a 3F catheter with a radiopaque marker and curved tip was passed from the right jugular vein into the main pulmonary artery under fluoroscopic guidance (Picker C-arm fluoroscope), as described previously (9,18). Left ventricular end-diastolic pressure was measured in some experiments by placement of a 3F radiopaque catheter in the chamber under fluoroscopic guidance.…”
Section: Methodsmentioning
confidence: 99%
“…A similar method has been previously used in the intact rat. 29,30 To study flow-induced vasodilation in the pulmonary vascular bed, the mice were cooled or heated to body temperatures ranging from 29°C to 41°C (as measured by the thermistor probe in the aortic arch), and cardiac output and pulmonary arterial pressure were evaluated in animals 1 day after administration of vehicle, AdCMV␤gal, and AdCMVeNOS. Pressure-flow relationships were derived by plotting pulmonary blood flow (cardiac output) against mean pulmonary arterial pressure.…”
Section: Measurement Of Pulmonary Vascular Responses and Cardiac Outputmentioning
confidence: 99%