2018
DOI: 10.1007/s10765-018-2368-1
|View full text |Cite
|
Sign up to set email alerts
|

Novel Calibration Technique for a Coulometric Evolved Vapor Analyzer for Measuring Water Content of Materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 3 publications
0
3
0
Order By: Relevance
“…While certified reference materials with known water content are frequently used, their availability is often limited, and they may not always offer suitable values or materials that guarantee both SI traceability and well-characterised uncertainty [16]. An alternative calibration approach is presented in [17], which utilises the water content of humid gas with a defined dewpoint as a reference. This approach provides traceability to the SI through national humidity standards, offering a reliable foundation for calibration.…”
Section: Lne-cetiat Reference Method: Evolved Eater Vapour Coulometri...mentioning
confidence: 99%
“…While certified reference materials with known water content are frequently used, their availability is often limited, and they may not always offer suitable values or materials that guarantee both SI traceability and well-characterised uncertainty [16]. An alternative calibration approach is presented in [17], which utilises the water content of humid gas with a defined dewpoint as a reference. This approach provides traceability to the SI through national humidity standards, offering a reliable foundation for calibration.…”
Section: Lne-cetiat Reference Method: Evolved Eater Vapour Coulometri...mentioning
confidence: 99%
“…In chemistry, PMMs are gravimetry, titrimetry, isotope dilution mass spectrometry and coulometry [12], an example of the latter being EWV. Despite being PMMs, recent publications have demonstrated the usefulness of calibrating EWV and Karl Fischer titration (KFT), when highly accurate results are desired [13][14][15]. As PMMs, EWV and KFT are used to calibrate secondary measurement methods, to ensure traceability to SI units [10,16].…”
Section: Introductionmentioning
confidence: 99%
“…Thus, the traceability to SI is obtained through traceable measurements of sample mass, flow rate, temperature and dew-point temperature. More detailed information about the NPL standard is given in [6]. which were analysed to ensure the reliability of the results.…”
Section: Introductionmentioning
confidence: 99%