2021
DOI: 10.1016/j.porgcoat.2021.106496
|View full text |Cite
|
Sign up to set email alerts
|

Novel C3N4/PANI@PA for enhancement of fire protection and smoke suppression in intumescent fire retardant epoxy coatings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 30 publications
0
13
0
Order By: Relevance
“…3e) shows the presence of –CN– (397.7 eV), –N– (400.2 eV) and –NH 4+ (405.5 eV). 30 The C 1s and N 1s spectrums indicate the successful preparation of PC by combining PANI and g-C 3 N 4 . 38 Moreover, Ti 2p (Fig.…”
Section: Resultsmentioning
confidence: 92%
“…3e) shows the presence of –CN– (397.7 eV), –N– (400.2 eV) and –NH 4+ (405.5 eV). 30 The C 1s and N 1s spectrums indicate the successful preparation of PC by combining PANI and g-C 3 N 4 . 38 Moreover, Ti 2p (Fig.…”
Section: Resultsmentioning
confidence: 92%
“…However, the PSPR and TSR values of the MF-1.5 foam reduce by 44.2 and 4.8% compared with that of the MF-0 foam, respectively. The drop in PSPR and TSR values indicates that the incorporated GP can play a positive role in the smoke suppression effect, and the av-EHC measures the combustion extent of pyrolysis gases in the gas phase . In Table , MF-1.5 attains an av-EHC value of 8.2 MJ/kg, which is 4.4 and 7.6 MJ/kg less than that of MF and MF-0 foams, respectively, demonstrating the existence of a gas-phase flame-retardant effect.…”
Section: Resultsmentioning
confidence: 94%
“…The drop in PSPR and TSR values indicates that the incorporated GP can play a positive role in the smoke suppression effect, and the av-EHC measures the combustion extent of pyrolysis gases in the gas phase. 38 In Table 2, MF-1.5 attains an av-EHC value of 8.2 MJ/kg, which is 4.4 and 7.6 MJ/kg less than that of MF and MF-0 foams, respectively, demonstrating the existence of a gas-phase flameretardant effect. The decrease in av-EHC is speculated to be caused by non-combustible gases released by the decomposition of GP, which can dilute the concentration of combustible gases.…”
Section: Cone Calorimeter Testsmentioning
confidence: 93%
“…Via the result of XPS and FTIR spectra curves, it can be inferred that the presence of P made the char layer structure change. The emergence of the stable P–O–C bond proved the generation of aromatic phosphor carbonaceous structure which formed a compact and dense char residue 60,73,74 …”
Section: Resultsmentioning
confidence: 99%
“…The emergence of the stable P-O-C bond proved the generation of aromatic phosphor carbonaceous structure which formed a compact and dense char residue. 60,73,74 The gas-phase flame retardant mechanism of AEP/IL is attributed to the following reasons: the introduction of AEP/IL suppresses the production of combustible gases (C=O and aromatic compounds). The non-combustible gases dilute the generated combustible gases and inhibit the combustion process.…”
Section: Gas Phase Analysismentioning
confidence: 99%