2013
DOI: 10.1016/j.corsci.2013.04.053
|View full text |Cite
|
Sign up to set email alerts
|

Novel benzimidazole derivatives as corrosion inhibitors of mild steel in the acidic media. Part I: Gravimetric, electrochemical, SEM and XPS studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
97
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 319 publications
(102 citation statements)
references
References 45 publications
4
97
0
1
Order By: Relevance
“…Several scientists in their studies (Table 3) reported similar results [2,4,6,[15][16][17][18][19], which confirm that the SSE act as effective inhibitors. The evolution in inhibition efficiency may be attributed to the adsorption of the particles at the carbon steel (X52) surfaces [20]. As the temperature increases, the corrosion rate (Cr) increases and inhibition efficiency decreases (Fig.…”
Section: Weight Loss Measurementsmentioning
confidence: 99%
“…Several scientists in their studies (Table 3) reported similar results [2,4,6,[15][16][17][18][19], which confirm that the SSE act as effective inhibitors. The evolution in inhibition efficiency may be attributed to the adsorption of the particles at the carbon steel (X52) surfaces [20]. As the temperature increases, the corrosion rate (Cr) increases and inhibition efficiency decreases (Fig.…”
Section: Weight Loss Measurementsmentioning
confidence: 99%
“…Only one capacitive loop at the higher frequency range is observed which means that the corrosion of CS is controlled by the charge transfer process [16,17]. The increasing diameter of loop obtained in 1 M H 2 SO 4 in the presence of EAE and BE indicated the corrosion inhibition and the strengthening of inhibitor film [18].…”
Section: Weight Loss Measurementsmentioning
confidence: 92%
“…Thus, as the values of obtained with the cefixima and aminobenzylpenicillin inhibitors are higher, this is an indication of the feasibility of adsorption of species drugs on the electrode surface, rather than desorption 59 . Moreover, the values of negative that got for both cefixima and aminobenzylpenicillin in inhibitors reflect the spontaneous nature of the adsorption and the constancy of the protective layer that forms on working surface [55,54]. Normally, a value of standard free energy up to " -20 kJ mol -1 " or less corresponds with the electrostatic interactions that exist between the charged surface electrode and the inhibitor species following the physisorption process.…”
Section: ………………(6)mentioning
confidence: 99%
“…However, this can only be used as a guide: it is not considered conclusive because of the water molecules on the electrode surface, which participate in a competitive adsorption process, while to remove them from the carbon steel surface electrode requires a significant activation energy [31,49]. This means that both the physisorption and chemisorption processes happen instantaneously 54 enabling the drug speciesto be adsorbed on the metal surface. On the basis of these indicators, it is possible to determine the relationship between the surface of the electrode and the corrosion inhibition so as to elucidate the type and strength of adsorption process.…”
Section: Effect Of Temperature and Adsorption Considerationsmentioning
confidence: 99%
See 1 more Smart Citation