Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2019
DOI: 10.18280/ria.330212
|View full text |Cite
|
Sign up to set email alerts
|

Novel Approach of Non-linearity Analyses of Resistive Temperature Sensors

Abstract: The non-linearity analysis is one of the most important issue when defining the static characteristics of temperature sensors, namely thermoresistive sensors. The purpose of this work is to propose a simple approach based on measuring the signal conditioning parameters to define the model of measured temperature. The developed approach is utilized to obtain a relationship between the bridge parameters and the final measured value of temperature. The data acquisition and signal processing are carried out by Ard… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0
3

Year Published

2019
2019
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 16 publications
0
2
0
3
Order By: Relevance
“…LabVIEW provides the ability to work with numeric, binary, string data, as well as groups and arrays. In addition, it is possible to output the result in the form of a graph, that is, the construction of graphs of various functions [18].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…LabVIEW provides the ability to work with numeric, binary, string data, as well as groups and arrays. In addition, it is possible to output the result in the form of a graph, that is, the construction of graphs of various functions [18].…”
Section: Methodsmentioning
confidence: 99%
“…Other works [14][15][16][17] illustrate several techniques, based on acoustic measurement that are applicable to measure several physical and chemical parameters such as: density of gases, temperature, displacement and concentration. These methods are based on creating a standing wave within a resonance tube (forced or free resonance mode of operation) and then the physical phenomenon based on acoustic measurement is acquired by a microphone and signal processing is performed using LabVIEW software [16].…”
Section: Literature Reviewmentioning
confidence: 99%
“…Dibandingkan dengan hasil kalibrasi pengkondisi sinyal RTD penelitian lain yang menggunakan digital controller E5EK Omron [21] dan Arduino Uno [12] untuk rentang temperatur 20 -50 0 C seperti pada Gambar 13, ketidaklinearan orde 2 (Second-Order Nonlinearity) hasil rancangan ini sangat kecil ditandai dengan nilai koefisien determinasi R 2 = 1. Tingkat linearitas hasil rancangan dan penelitian [12] dapat dikatakan lebih baik daripada penelitian [21].…”
Section: Hasil Dan Pembahasan a Kalibrasi Pengkondisi Sinyal Rtdunclassified
“…Simpangan rata-rata hasil kalibrasi pengkondisi sinyal RTDx01 rancangan jauh lebih kecil dari penelitian [12] yang bernilai 0,72 0 C (2,28%), namun sedikit lebih besar dari penelitian [21] yang bernilai 0,36 0 C (1,17%). Perbandingan hasil kalibrasi penelitian lain [12], [21] ini dapat dilihat pada Tabel II. Terdapat perbedaan hasil pengukuran antara pengkondisi sinyal rancangan RTDx01 terhadap Newport 267B.…”
Section: Hasil Dan Pembahasan a Kalibrasi Pengkondisi Sinyal Rtdunclassified
See 1 more Smart Citation