2013
DOI: 10.1097/brs.0b013e3182a0dbc5
|View full text |Cite
|
Sign up to set email alerts
|

Novel 3-Dimensional Motion Analysis Method for Measuring the Lumbar Spine Range of Motion

Abstract: N/A.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
48
0
3

Year Published

2014
2014
2019
2019

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 34 publications
(53 citation statements)
references
References 26 publications
2
48
0
3
Order By: Relevance
“…The maximal spinal ROM values exhibited in the present study were comparable to previously reported values (Edmondston et al, 2007;Peach et al, 1998;Tojima et al, 2013;Tsang et al, 2013;Van Herp et al, 2000;Willems et al, 1996). Discrepancies between the present results and past literature may be attributable to differences in data collection (for example, using an active head position in which the head moved in the direction of trunk motion, compared to a neutral head position (Schinkel-Ivy et al, 2014)) and Table 1 Mean (SD) R xy(time) values, comparing the angle time series for each adjacent pairing of clusters in each movement task.…”
Section: Discussionsupporting
confidence: 92%
“…The maximal spinal ROM values exhibited in the present study were comparable to previously reported values (Edmondston et al, 2007;Peach et al, 1998;Tojima et al, 2013;Tsang et al, 2013;Van Herp et al, 2000;Willems et al, 1996). Discrepancies between the present results and past literature may be attributable to differences in data collection (for example, using an active head position in which the head moved in the direction of trunk motion, compared to a neutral head position (Schinkel-Ivy et al, 2014)) and Table 1 Mean (SD) R xy(time) values, comparing the angle time series for each adjacent pairing of clusters in each movement task.…”
Section: Discussionsupporting
confidence: 92%
“…Based on a previous protocol5, 14 ) , seven spherical markers were placed, 14 mm in diameter, on the following anatomical landmarks: right and left posterior superior iliac spine (PSIS), right and left of the T11 spinous process over the paravertebral muscles, and the T10, T12, and S3 spinous processes. Spherical markers for the Plug-in-Gait model15, 16 ) in addition to our own marker set were attached.…”
Section: Methodsmentioning
confidence: 99%
“…Based on the static position, lumbar spine angle5, 14 ) and hip angle15, 16 ) were calculated. The code data obtained during trunk bending to the left side were converted to match the code data from trunk bending to the right side.…”
Section: Methodsmentioning
confidence: 99%
“…사체를 이용한 연구 로 요추의 수동적인 최대 가동범위 측정은 가능하나 살아 있는 생체가 아니기 때문에 살아 있는 인체의 운동 및 능동 적인 가동범위를 측정, 분석하는 방법으로는 분명한 한계 가 있다. 입체사진측량기법(stereophotogrammetry)을 활 용한 요추의 운동 및 가동범위 측정법은 비침습적으로 요 추 가동범위를 측정할 수 있으나 실시간으로 인체의 운동 을 분석하지 못하는 단점이 있다 9) . 일차원적인 관절 가동범위와 요통의 상관성보다 요추 관 절 운동의 패턴이 요통의 병리적인 인과관계일 수 있다는 연구가 있었다 10) .…”
Section: ⅰ 서 론unclassified
“…이에 따라 요추의 운동 패턴의 이해 수단에 대한 수요가 점차 발생하고 있다 11) . 이러한 요구에 동작 분석 시스템인 VICON system(VICON Motion Systems Ltd, Oxford, United Kingdom)은 인체 의 운동을 분석, 근골격계의 운동 및 관절 가동범위를 평가 할 수 있다는 장점이 있지만 시스템 설치에 넓은 공간 및 많은 비용이 필요하여 1, 2차 의료기관에서 간편하게 사용 할 인체의 운동 평가도구로는 한계가 있다 9) . 이런 문제점 을 보완하기 위해 경제적이고 휴대하기 편리하며 실시간 및 비침습적으로 관절운동범위(range of motion, 이하 ROM)정보를 수집해 인체의 운동을 3차원으로 평가하고 분석할 수 있는 검사도구인 관성측정장치(inertial measurement unit, 이하 IMU)를 이용한 측정 시스템이 제안 되어 요추 및 경추 관절 운동 측정 시 활용되었다 [12][13][14] .…”
Section: ⅰ 서 론unclassified