2007
DOI: 10.1016/j.jchromb.2007.08.012
|View full text |Cite
|
Sign up to set email alerts
|

Normal phase and reverse phase HPLC-UV-MS analysis of process impurities for rapamycin analog ABT-578: Application to active pharmaceutical ingredient process development

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2008
2008
2015
2015

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 26 publications
0
4
0
Order By: Relevance
“…Analysis was carried out for RPM by reverse phase HPLC (RP-HPLC) (Shimadzu UFLC model) on C-18 column Inertsil Õ (Octadecylsilane[ODS]-3 V, dimension 4.6 Â 250 mm) with a mobile phase of methanol-water (90:10 v/v) in isocratic mode at a flow rate of 1 ml/min with 278 nm as the analytical wavelength and 20 ml injection volume Khan et al, 2013). Similarly for PIP, analysis was carried out by RP-HPLC (Shimadzu UFLC model) on C-18 column Inertsil Õ (ODS-3 V, dimension 4.6 Â 250 mm) with a mobile phase of acetonitrile-water (60:40 v/v) in isocratic mode at a flow rate of 1.5 ml/min with 343 nm as analytical wavelength and 20 ml injection volume (Chen et al, 2007). Calibration curves were prepared in the concentration range of 0.1-50 and 0.25-50 mg/ml for RPM and PIP, respectively.…”
Section: Entrapment Efficiency Of Nanoparticlesmentioning
confidence: 99%
“…Analysis was carried out for RPM by reverse phase HPLC (RP-HPLC) (Shimadzu UFLC model) on C-18 column Inertsil Õ (Octadecylsilane[ODS]-3 V, dimension 4.6 Â 250 mm) with a mobile phase of methanol-water (90:10 v/v) in isocratic mode at a flow rate of 1 ml/min with 278 nm as the analytical wavelength and 20 ml injection volume Khan et al, 2013). Similarly for PIP, analysis was carried out by RP-HPLC (Shimadzu UFLC model) on C-18 column Inertsil Õ (ODS-3 V, dimension 4.6 Â 250 mm) with a mobile phase of acetonitrile-water (60:40 v/v) in isocratic mode at a flow rate of 1.5 ml/min with 343 nm as analytical wavelength and 20 ml injection volume (Chen et al, 2007). Calibration curves were prepared in the concentration range of 0.1-50 and 0.25-50 mg/ml for RPM and PIP, respectively.…”
Section: Entrapment Efficiency Of Nanoparticlesmentioning
confidence: 99%
“…Other LC modes, such as normal phase [33,34], ion exchange [35], ion-pairing [36,37] and hydrophilic interaction chromatography (HILIC) [38,39], in addition to alternative separation methodologies, such capillary electrophoresis (CE) [40,41], have also been used, although to a lesser extent. CE stands out for its advantageous sensitivity, eco-friendliness, resolution and high efficiency; but it is not as precise as HPLC.…”
Section: General Questionsmentioning
confidence: 99%
“…Sirolimus (34; Rapamune, Wyeth) was originally discovered from bacterium Steptomyces hygroscopicus with promising antifungal activity 467,468 and is being used along with other coronary stents against restenosis of coronary arteries due to balloon angioplastyis. Zotarolimus (53) is an active principle of Endeavor™ (tradename) stent that inhibits cell proliferation, preventing scar tissue formation and minimizes restenosis in angioplasty patients [469]. In July 2005, Medtronic received European approval for the sale of the Endeavor drug-eluting coronary stent that consists of a cobalt-based alloy integrated with a biomimetic phosphorylcholine polymer.…”
Section: Dronabinol and Cannabidolmentioning
confidence: 99%