Normal and malaligned talonavicular fusion alters cadaveric foot pressure and kinematics

Elizabeth P. Wahl,
William D. Lin,
Eric C. Whittaker
et al.

Abstract: Talonavicular (TN) fusion is a common treatment for TN arthritis or deformity correction. There is incongruous evidence regarding remaining motion at the talocalcaneal and calcaneocuboid joints after TN fusion. Additionally, the effects of a malaligned TN fusion are not well understood and alignment of the fusion may be important for overall foot integrity. This project assessed the kinematic and kinetic effects of neutral and malaligned TN fusions. Ten cadaveric feet were tested on a gait simulator in four co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 38 publications
0
1
0
Order By: Relevance
“…Adaptive compensation is where other sensors, such as a contact pressure sensor, can be placed in the control loop and combined with force or position control so that joint loads, motions, and contact pressure can all be controlled on different DOF. 40,41 Depending on the software being used, the control type may or may not be capable of adaptive compensation or hybrid force/position control. Solutions that provide different control types for each DOF and smoothly transition between types throughout a loading profile will provide the greatest flexibility for answering a wide variety of clinical questions.…”
Section: What Measurements Are Needed For Each Surgical or Experiment...mentioning
confidence: 99%
“…Adaptive compensation is where other sensors, such as a contact pressure sensor, can be placed in the control loop and combined with force or position control so that joint loads, motions, and contact pressure can all be controlled on different DOF. 40,41 Depending on the software being used, the control type may or may not be capable of adaptive compensation or hybrid force/position control. Solutions that provide different control types for each DOF and smoothly transition between types throughout a loading profile will provide the greatest flexibility for answering a wide variety of clinical questions.…”
Section: What Measurements Are Needed For Each Surgical or Experiment...mentioning
confidence: 99%