2018
DOI: 10.1021/acs.analchem.8b00356
|View full text |Cite
|
Sign up to set email alerts
|

Nontargeted Identification of Tracer Incorporation in High-Resolution Mass Spectrometry

Abstract: "Fluxomics" refers to the systematic analysis of metabolic fluxes in a biological system and may uncover novel dynamic properties of metabolism that remain undetected in conventional metabolomic approaches. In labeling experiments, tracer molecules are used to track changes in the isotopologue distribution of metabolites, which allows one to estimate fluxes in the metabolic network. Because unidentified compounds cannot be mapped on pathways, they are often neglected in labeling experiments. However, using rec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
16
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(16 citation statements)
references
References 23 publications
0
16
0
Order By: Relevance
“…Both ion source gases GS1 (gas 1) and GS2 (gas 2) were set at 40 psi while the curtain gas was set at 35 psi. Untargeted analysis was performed using geoRge (Capellades et al., 2016), DynaMet (Kiefer et al., 2015) and HiResTEC (Hoffmann et al., 2018) while a proprietary software, MultiQuant TM 3.0.1 (SCIEX, Framingham, MA), was used for the targeted analysis. Peak areas for the monoisotopic peaks and the isotopologues were integrated for the respective mean m/z values and m/z tolerance of ±0.05 ​Da and retention time window of ±30 ​s.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Both ion source gases GS1 (gas 1) and GS2 (gas 2) were set at 40 psi while the curtain gas was set at 35 psi. Untargeted analysis was performed using geoRge (Capellades et al., 2016), DynaMet (Kiefer et al., 2015) and HiResTEC (Hoffmann et al., 2018) while a proprietary software, MultiQuant TM 3.0.1 (SCIEX, Framingham, MA), was used for the targeted analysis. Peak areas for the monoisotopic peaks and the isotopologues were integrated for the respective mean m/z values and m/z tolerance of ±0.05 ​Da and retention time window of ±30 ​s.…”
Section: Methodsmentioning
confidence: 99%
“…Metabolites were extracted from samples quenched at 0, 5, 10, 20, 30, 60, 120, 300, and 600s time points after the introduction of the 13 C tracer. For this dataset X 13 CMS (Patti and CMS, 2014), geoRge (Capellades et al., 2016) and HiResTEC (Hoffmann et al., 2018) were used as the test software for comparative analysis with the reference software, DynaMet (Kiefer et al., 2015).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations