2012
DOI: 10.1109/tbme.2012.2208964
|View full text |Cite
|
Sign up to set email alerts
|

Nonlocal Means Denoising of ECG Signals

Abstract: Patch-based methods have attracted significant attention in recent years within the field of image processing for a variety of problems including denoising, inpainting, and super-resolution interpolation. Despite their prevalence for processing 2-D signals, they have received little attention in the 1-D signal processing literature. In this letter, we explore application of one such method, the nonlocal means (NLM) approach, to the denoising of biomedical signals. Using ECG as an example, we demonstrate that a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
121
0
3

Year Published

2014
2014
2024
2024

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 198 publications
(124 citation statements)
references
References 9 publications
0
121
0
3
Order By: Relevance
“…To evaluate the performance of the proposed ESMD-based NLM (ESMD-NLM) method, we have chosen four other denoising methods for comparison including the NLM method [24], the VMD method [29], the EEMD method [17] and the median (MED) filter [6]. Experiments have been conducted on the simulated ECG signals corrupted with Gaussian white noise and muscle artifact (MA) noise as well as the real ECG signals downloaded from MIT-BIH database, QT database and MIH-BIH ECG compression test database [29].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…To evaluate the performance of the proposed ESMD-based NLM (ESMD-NLM) method, we have chosen four other denoising methods for comparison including the NLM method [24], the VMD method [29], the EEMD method [17] and the median (MED) filter [6]. Experiments have been conducted on the simulated ECG signals corrupted with Gaussian white noise and muscle artifact (MA) noise as well as the real ECG signals downloaded from MIT-BIH database, QT database and MIH-BIH ECG compression test database [29].…”
Section: Resultsmentioning
confidence: 99%
“…Based on the assumption that patterns of an image are often self-similar and redundant, the NLM method replaces a pixel considered noisy with the weighted average of all the pixels in the whole image or a pre-defined search window, where the weights are robustly determined by the nonlocal comparison of image patches instead of individual pixels. Because the NLM can achieve adequate noise suppression and excellent detail preservation results, Tracey and Miller have recently applied it to ECG signal denoising [24]. However, the NLM method cannot suppress noise in highly corrupted ECG signals well because it involves inaccurate weight computation based on noisy signals, which will lead to degraded restoration performance.…”
Section: Introductionmentioning
confidence: 99%
“…The weight, ω(i, j), takes a large value if the neighbourhood of sample i is similar to the neighbourhood of sample j; otherwise it takes a small value. It is computed as [31,32] v…”
Section: Nlm Algorithmmentioning
confidence: 99%
“…The ECG signal could be affected by several types of noise, which influence negatively on this signal [10][11][12]. e.g., the baseline wandering, the high frequency noise and the power line interference.…”
Section: Introductionmentioning
confidence: 99%