Diagnostic Ultrasound Imaging: Inside Out 2014
DOI: 10.1016/b978-0-12-396487-8.00012-4
|View full text |Cite
|
Sign up to set email alerts
|

Nonlinear Acoustics and Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 132 publications
0
7
0
Order By: Relevance
“…Uniform tissue was used for the remaining distances. The parameters α0 = 0.00220 dB/(cm MHz) [31], b = 2, c = 1482.3 m/s, density ρ = 1000 kg/m 3 , and B/A = 4.96 [33] were used for the simulation of the propagation in water. Although the experimental work was conducted in prostate adenocarcinoma, parameters for human prostate tissue were used in the simulations.…”
Section: Simulation Of Arfmentioning
confidence: 99%
See 1 more Smart Citation
“…Uniform tissue was used for the remaining distances. The parameters α0 = 0.00220 dB/(cm MHz) [31], b = 2, c = 1482.3 m/s, density ρ = 1000 kg/m 3 , and B/A = 4.96 [33] were used for the simulation of the propagation in water. Although the experimental work was conducted in prostate adenocarcinoma, parameters for human prostate tissue were used in the simulations.…”
Section: Simulation Of Arfmentioning
confidence: 99%
“…With b=1.3 and f=5 MHz, (2) yields α0=0.48 dB/(cm MHz 1.3 ), which was used in the simulations. The other parameters were c = 1561 m/s [34], ρ = 1045 kg/m 3 [35] and B/A = 7.43 (B/A of muscle [33]).…”
Section: Simulation Of Arfmentioning
confidence: 99%
“…The parameters for water were: 𝛼 = 0. 025 Np/m [31], 𝑏 = 2, 𝑐 = 1482 m/s, density 𝜌 = 1000 kg/m 3 , and nonlinearity parameter (B/A) = 4.96 [33] and for collagen gel: 𝛼 = 0.18 Np/m [34], 𝑏 = 1.6 [34], c = 1496 m/s [35], 𝜌 = 1116 kg/m 3 [35] and B/A = 7.43 (B/A of muscle [33] due to lack of experimental data for collagen gel). The surface transducer pressures used as input parameters in simulation of the ARF were determined as described in Appendix A, and found to be 105, 146 and 206 kPa for peak negative pressures of 2.2, 2.7 and 3.0 MPa.…”
Section: ) Arf Estimationmentioning
confidence: 99%
“…Echolocation is the use of reflected sound to locate and identify objects, particularly used by animals like dolphins and bats. According to [Szabo 2014], bats emit ultrasound pulses, ranging between 20-150 kHz, to catch an insect prey with a resolution of 2-15 mm. This involves signal processing such as:…”
Section: Echolocationmentioning
confidence: 99%
“…PW is preferred for theoretical and empirical reasons. First, the transmission frequency 𝑓 0 may experience considerable downshift as a result of absorption and diffraction effects [Szabo 2014]. Therefore, using pulsed waves independent for each emission is theoretically better than continuous waves compared to 𝑓 0 .…”
Section: Sound Sourcementioning
confidence: 99%