Review of Progress in Quantitative Nondestructive Evaluation 1991
DOI: 10.1007/978-1-4615-3742-7_71
|View full text |Cite
|
Sign up to set email alerts
|

Nonlinear Acoustics, a Technique to Determine Microstructural Changes in Materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
41
0

Year Published

1997
1997
2020
2020

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 56 publications
(42 citation statements)
references
References 7 publications
1
41
0
Order By: Relevance
“…5, where ~ is plotted as a function of fundamental amplitude. It is common to see ~ values to increase very quickly below a particular level of the fundamental [8,10], as seen in the curves of Fig 5. This artificial increase in ~ is known to be the result of the second hannonic amplitude falling below the noise floor, appearing to remain constant for ever decreasing levels of the fundamental amplitude. From Eq.…”
Section: Initial Results (3)mentioning
confidence: 87%
See 1 more Smart Citation
“…5, where ~ is plotted as a function of fundamental amplitude. It is common to see ~ values to increase very quickly below a particular level of the fundamental [8,10], as seen in the curves of Fig 5. This artificial increase in ~ is known to be the result of the second hannonic amplitude falling below the noise floor, appearing to remain constant for ever decreasing levels of the fundamental amplitude. From Eq.…”
Section: Initial Results (3)mentioning
confidence: 87%
“…This broadband technique establishes the empirical conversion efficiency for the receiving transducer as a function of frequency and includes the effects of the coupling media, allowing the calculation of absolute displacement amplitudes. Details of the calibration technique have been described elsewhere [7,8]. This contact transducer technique was chosen because sensitivity and signal-to-noise are reasonable and sample preparation is relatively easy, with reasonable results obtained from surfaces prepared by polishing with 600 grit abrasives.…”
Section: Acoustic Harmonic Genera Non Measurementsmentioning
confidence: 99%
“…The calibration was conducted to obtain the transfer function that converts the electrical output of the receiving transducer into displacement amplitude. The transfer function was obtained using the broadband pulse-echo technique [10]. The calibration was conducted only for the 10 MHz transducer that was used as the receiver in the nonlinear measurement.…”
Section: Absolute Measurementmentioning
confidence: 99%
“…Received signal was processed through fast Fourier transform (FFT) to obtain ( ). From the experimental results of calibration and nonlinear measurement, the displacement amplitude spectrum of the current output spectrum ( ) as follows [5], ( ) …”
Section: -3mentioning
confidence: 99%
See 1 more Smart Citation