2008
DOI: 10.1016/j.atherosclerosis.2007.11.035
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive real-time imaging of intima thickness after rat carotid artery balloon injury using ultrasound biomicroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
25
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 34 publications
(27 citation statements)
references
References 18 publications
2
25
0
Order By: Relevance
“…Ultrasound biomicroscopy has been shown to be a useful tool for the assessment of intimal hyperplasia and lumen diameter in the rat carotid injury model [19]. In this study, a high-resolution ultrasound system (Vevo 2100; Visualsonics Inc., Toronto, Ont., Canada), equipped with a MS700 transducer (up to 70 MHz), was used for in vivo evaluation of intimal hyperplasia and lumen diameter of the carotid arteries 2 and 4 weeks after the injury.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Ultrasound biomicroscopy has been shown to be a useful tool for the assessment of intimal hyperplasia and lumen diameter in the rat carotid injury model [19]. In this study, a high-resolution ultrasound system (Vevo 2100; Visualsonics Inc., Toronto, Ont., Canada), equipped with a MS700 transducer (up to 70 MHz), was used for in vivo evaluation of intimal hyperplasia and lumen diameter of the carotid arteries 2 and 4 weeks after the injury.…”
Section: Methodsmentioning
confidence: 99%
“…The passage was repeated three times in order to remove the endothelial layer. The external carotid artery was then ligated and the skin wound closed [19]. The animal was then turned onto its stomach, the osmotic ALZET® pump was placed subcutaneously on the back and the skin wound was closed.…”
Section: Methodsmentioning
confidence: 99%
“…6 UBM measurements of IMT and plaque thickness in various animal studies have been compared with histological data showing close correlations between the methods. 7,8 Moreover, we have published the results of in vitro measurements of IT and MT of human mesenteric arteries by UBM, demonstrating close correlations to histological measurements. 9 In that study the discrimination capacity of UBM was tested with silicon layer phantoms (measuring 1-200 μm) showing high accuracy.…”
Section: Introductionmentioning
confidence: 99%
“…Carotid artery balloon injury in rats is a well-established model to study the initial response to vascular injury 20 and triggers remodeling and neointima formation via SMC proliferation and survival as depicted in Figure 2A.…”
Section: Mir-210 Is Repressed In Experimental Carotid Artery Remodelingmentioning
confidence: 99%
“…Injury of the common carotid artery in rats was performed as previously described 20 in accordance with the Guide for the Care and Use of Laboratory Animals published by the US National Institutes of Health (NIH Publication No. 85-23, revised 1996).…”
Section: Rat Carotid Artery Balloon Injury Modelmentioning
confidence: 99%