1993
DOI: 10.1109/42.251121
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive measurement of regional cerebral blood flow change with H/sub 2//sup 15/O and positron emission tomography using a mechanical injector and a standard arterial input function

Abstract: To estimate changes in regional cerebral blood flow (rCBF) without arterial sampling in the study of functional-anatomical correlations in the human brain, using (15)O-labeled water and PET, a standard arterial input function was generated from the input function in 10 normal volunteers with dose calibration and peak time normalization. The speed and volume of injection were precisely controlled with a mechanical injector. After global normalization of each tissue activity image, the standard arterial input fu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

1994
1994
1998
1998

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(3 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“…The dedicated PET camera, HEADTOME IV (Shimadzu, Kyoto, Japan), provides 14 slices of tomographic images at 6.5-mm intervals with spatial resolution of 7.5-mm full-width-halfmaximum (FWHM) and axial resolution of 10-mm FWHM. The CBF images were created using the autoradiographic method with a standard input function [16], [17]. The CBF images of each subject were three-dimensionally registered to the MRI of the subject [18].…”
Section: B Pet Activation Study and Mrimentioning
confidence: 99%
“…The dedicated PET camera, HEADTOME IV (Shimadzu, Kyoto, Japan), provides 14 slices of tomographic images at 6.5-mm intervals with spatial resolution of 7.5-mm full-width-halfmaximum (FWHM) and axial resolution of 10-mm FWHM. The CBF images were created using the autoradiographic method with a standard input function [16], [17]. The CBF images of each subject were three-dimensionally registered to the MRI of the subject [18].…”
Section: B Pet Activation Study and Mrimentioning
confidence: 99%
“…0-15 labeled water (in total 6 ml saline solution) was injected via the right cubital vein in 15 seconds with an automatic injector. 9 The volume and activity of the residual radiotracer in the syringe were measured and corrected for decay to obtain the injected dose. The injected activity ranged from 11 to 39 mCi (410 to 1440 MBq).…”
Section: Tomograph Characteristicsmentioning
confidence: 99%
“…The final technique is to use a standard input function (averaged over several normal controls) to calculate the physiological parameters [11] [12]. There has also been considerable interest in modeling the input function [13] [14].…”
mentioning
confidence: 99%