1991
DOI: 10.1378/chest.100.2.371
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive Measurement of Central Venous Pressure by Neck Inductive Plethysmography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

1996
1996
2016
2016

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 3 publications
0
6
0
Order By: Relevance
“…Even though there were some other noninvasive methods of CVP measurement, such as controlled compression sonography on the peripheral vein, 20,21 forearm volume plethysmography, 22,23 and neck inductive plethysmography, 24 they relied on additional instruments that are not readily available in routine clinical practice. By contrast, the instruments that we use in the new method of quantification of CVP are just a ruler and a pencil besides a portable ultrasound machine, which is widely available.…”
Section: Discussionmentioning
confidence: 99%
“…Even though there were some other noninvasive methods of CVP measurement, such as controlled compression sonography on the peripheral vein, 20,21 forearm volume plethysmography, 22,23 and neck inductive plethysmography, 24 they relied on additional instruments that are not readily available in routine clinical practice. By contrast, the instruments that we use in the new method of quantification of CVP are just a ruler and a pencil besides a portable ultrasound machine, which is widely available.…”
Section: Discussionmentioning
confidence: 99%
“…9 Previous attempts at noninvasive hemodynamic monitoring using plethysmography, thoracic electrical bioimpedance, and external Doppler probes have shown these methods to be cumbersome or inaccurate. [10][11][12][13] Other investigators have used echocardiography 14,15 and handheld ultrasound 16 to image the diameter of the inferior vena cava in order to assess intravascular volume status, but these techniques require expertise in sonographic imaging. An alternative technique is to measure peripheral venous pressure, which correlates with CVP.…”
Section: Discussionmentioning
confidence: 99%
“…However, noninvasive methods lack the accuracy and precision for routine use, and minimal invasive techniques which include cannulating peripheral limb veins, external jugular vein (EJV) have shown mixed results when compared with invasive CVP (CVPi). [ 6 7 8 9 10 11 12 13 14 15 ]…”
Section: Introductionmentioning
confidence: 99%