2010
DOI: 10.1117/1.3462996
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive imaging of prefrontal activation during attention-demanding tasks performed while walking using a wearable optical topography system

Abstract: Abstract. Optical topography ͑OT͒ based on near-infrared spectroscopy is a noninvasive technique for mapping the relative concentration changes in oxygenated and deoxygenated hemoglobin ͑oxy-and deoxy-Hb, respectively͒ in the human cerebral cortex. In our previous study, we developed a small and light wearable optical topography ͑WOT͒ system that covers the entire forehead for monitoring prefrontal activation. In the present study, we examine whether the WOT system is applicable to OT measurement while walking… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
88
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 73 publications
(89 citation statements)
references
References 31 publications
1
88
0
Order By: Relevance
“…The details of the WOT-100 (Hitachi High-Technologies Corporation Co. Ltd., Tokyo, Japan) have been described in a previous study [19,20]. The probe unit has a 2 × 8 alternating arrangement of irradiation and detection positions covering the entire forehead, with 22 measurement points (Figure 3 (A)).…”
Section: Methodsmentioning
confidence: 99%
“…The details of the WOT-100 (Hitachi High-Technologies Corporation Co. Ltd., Tokyo, Japan) have been described in a previous study [19,20]. The probe unit has a 2 × 8 alternating arrangement of irradiation and detection positions covering the entire forehead, with 22 measurement points (Figure 3 (A)).…”
Section: Methodsmentioning
confidence: 99%
“…The details of the WOT system are described previously. [27][28][29] The WOT system is small, light, and covers the entire forehead. The probe positions of the light sources and detectors and the channel positions of the WOT system are shown in Fig.…”
Section: Near-infrared-spectroscopy Measurementmentioning
confidence: 99%
“…A WOT system, the same one used in our previous study, 29 was used for measuring cerebral blood-volume change of the 12 participants. The system generally measures the changes in the product of hemoglobin (Hb) concentration (C) and effective optical path length (L), called simply "Hb change ( CL)" here, in human-brain tissue, such as the cerebral cortex.…”
Section: Near-infrared-spectroscopy Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…In baseline correction, we defined a period starting from the onset of the task condition to the end of each task condition as one analysis block. Then, we applied linear regression by least mean squares to determine the linear trend of its baseline [62,63]. Finally, data were averaged in all the analysis blocks [64].…”
Section: Pre-processingmentioning
confidence: 99%