2015
DOI: 10.7863/ultra.34.1.111
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive Imaging of Aortic Atherosclerosis by Ultrasound Biomicroscopy in a Mouse Model

Abstract: Ultrasound biomicroscopy could be used for a noninvasive, accurate, and dynamic analysis of aortic atherosclerosis in LDL-R knockout mice.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 12 publications
0
8
0
1
Order By: Relevance
“…Cine loop images were later analyzed using Vevo 2100 software. Intima-media thickness was calculated using previously validated approach(Zhang et al, 2015) i.e. from edge of echo toward the blood stream (intima) to other echo edge (adventitia) using ImageJ (National Institutes of Health).…”
Section: Star Methodsmentioning
confidence: 99%
“…Cine loop images were later analyzed using Vevo 2100 software. Intima-media thickness was calculated using previously validated approach(Zhang et al, 2015) i.e. from edge of echo toward the blood stream (intima) to other echo edge (adventitia) using ImageJ (National Institutes of Health).…”
Section: Star Methodsmentioning
confidence: 99%
“…We suspected that the above results may be caused by abnormal lipid metabolism, which also suggested that alisol A may exert antiatherosclerotic effect by lowering plasma lipids. The non-invasive high-resolution small animal ultrasound system makes it possible to perform quantitative assessment in live mice, although the imaging plaque could be affected by the equipment and operator's experience (Zhang et al, 2015). The results of non-invasive small animal ultrasound examination in the mice three months after the drug administration demonstrated no statistical difference among the groups.…”
Section: Discussionmentioning
confidence: 98%
“…Ultrasound bio-microscopy enables evaluation of plaque size and stenosis in vivo, noninvasively, and in real-time [ 17 , 23 25 ], which has been widely used to detect spontaneously formed plaques in the brachiocephalic [ 26 , 27 ], thoracic arteries [ 24 , 28 ], and the ascending aorta [ 23 ]. In this study, such technique is used to monitor the development of plaque of atherosclerosis and such technique will give the longitudinal study possible.…”
Section: Discussionmentioning
confidence: 99%