Noninvasive in vivo plasma volume and hematocrit in humans: observing long-term baseline behavior to establish homeostasis for intravascular volume and composition

Abstract: A new device incorporating a new algorithm and measurement process allows simultaneous noninvasive in vivo monitoring of intravascular plasma volume and red blood cell volume. The purely optical technique involves probing fingertip skin with near infrared laser light and collecting the wavelength shifted light, that is, the inelastic emission (IE) which includes the unresolved Raman and fluorescence, and the un-shifted emission, that is, the elastic emission (EE) which includes both the Rayleigh and Mie scatte… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 20 publications
0
1
0
Order By: Relevance
“…[27][28][29] PVOH routinely measures physiological variations of Hct of 0.25% so the standard deviation of the measurements must be better than that. Our current estimate indicates that PVOH can measure a change of Hct of ±0.07 on a Hct of 28 in 3 s. 30 Furthermore, if one chooses to exclude the possibility of obtaining Raman information, then the entire PVOH unit can be implemented as a one laser-2 single-channel detector unit, as small and light as any pulse oximeter. 21,22 And, if one can implement PV[O]H using LEDs instead of lasers, with currently available COTS LEDs, and using only fluorescence as the IE, we may see wearable PVOH units.…”
Section: Enter Raman Spectroscopymentioning
confidence: 93%
“…[27][28][29] PVOH routinely measures physiological variations of Hct of 0.25% so the standard deviation of the measurements must be better than that. Our current estimate indicates that PVOH can measure a change of Hct of ±0.07 on a Hct of 28 in 3 s. 30 Furthermore, if one chooses to exclude the possibility of obtaining Raman information, then the entire PVOH unit can be implemented as a one laser-2 single-channel detector unit, as small and light as any pulse oximeter. 21,22 And, if one can implement PV[O]H using LEDs instead of lasers, with currently available COTS LEDs, and using only fluorescence as the IE, we may see wearable PVOH units.…”
Section: Enter Raman Spectroscopymentioning