Noninvasive electrocardiographic mapping to guide ablation of outflow tract ventricular arrhythmias

Abstract: BackgroundLocalizing the origin of outflow tract ventricular tachycardias (OTVT) is hindered by lack of accuracy of electrocardiographic (ECG) algorithms and infrequent spontaneous premature ventricular complexes (PVCs) during electrophysiological studies.ObjectivesTo prospectively assess the performance of noninvasive electrocardiographic mapping (ECM) in the pre-/periprocedural localization of OTVT origin to guide ablation and to compare the accuracy of ECM with that of published ECG algorithms.MethodsPatien… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

4
63
0
4

Year Published

2015
2015
2020
2020

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 81 publications
(71 citation statements)
references
References 16 publications
(12 reference statements)
4
63
0
4
Order By: Relevance
“…[10][11][12] Specifically, two studies compared accuracy of PVC mapping using ECVUE with the standard 12-lead body surface ECG. 10,11 In both studies, ECVUE was first used to localize the PVC origin to either the right or left chamber, and second to sublocalize the origin within the ventricular chambers. Jamil-Copley and coworkers 10 conducted a prospective single-center study, which included 24 patients, most of whom had idiopathic PVCs emanating from the outflow tracts (Fig.…”
Section: Ablation Accuracy and Successmentioning
confidence: 99%
See 1 more Smart Citation
“…[10][11][12] Specifically, two studies compared accuracy of PVC mapping using ECVUE with the standard 12-lead body surface ECG. 10,11 In both studies, ECVUE was first used to localize the PVC origin to either the right or left chamber, and second to sublocalize the origin within the ventricular chambers. Jamil-Copley and coworkers 10 conducted a prospective single-center study, which included 24 patients, most of whom had idiopathic PVCs emanating from the outflow tracts (Fig.…”
Section: Ablation Accuracy and Successmentioning
confidence: 99%
“…AMC, aortomitral continuity; epi, epicardial; LCC, left coronary cusp; LV, left ventricle; NCC, noncoronary cusp; PH, parahissian; RCC, right coronary cusp; RV, right ventricle; TV, tricuspid valve. (Data from Refs [10][11][12]. …”
mentioning
confidence: 99%
“…In the first case, pacing is required via the mapping catheter and encompasses the epicardial mapping of the pacing spike with the ECVUE. 21 As only the site of earliest activation is informative for revealing the position of the mapping catheter, only the pacing spike is used for this approach. Moreover, pace match was visually evaluated to compare the isopotential map of the paced beat with that of a spontaneous beat (Fig.…”
Section: In Vivo Localization Of the Ablation Targetmentioning
confidence: 99%
“…The most frequently used IPM method is based on a homogeneous volume conductor model (VCM) constructed from computed tomography images 1. This technique is being applied increasingly for analysis of idiopathic ventricular foci and guidance of catheter ablation 2, 3…”
Section: Introductionmentioning