2007
DOI: 10.1111/j.1540-8159.2007.00627.x
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive Classification of Ventricular Preexcitation with Unshielded Magnetocardiography and Transesophageal Atrial Pacing and Follow‐Up

Abstract: MCG was more accurate than ECG for the classification of VPx and provided additional information in the non-invasive EP assessment of patients with WPW syndrome.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2007
2007
2008
2008

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 13 publications
0
8
0
Order By: Relevance
“…Some results have been reported in recent papers [8][9][10]. MCG 3D-EAI was successful in patients with WPW syndrome, atrial flutter and ventricular arrhythmias.…”
Section: Resultsmentioning
confidence: 72%
See 1 more Smart Citation
“…Some results have been reported in recent papers [8][9][10]. MCG 3D-EAI was successful in patients with WPW syndrome, atrial flutter and ventricular arrhythmias.…”
Section: Resultsmentioning
confidence: 72%
“…MCG can monitor and map quickly transient arrhythmic events whenever needed, even in emergency, without any discomfort and with very short data acquisition time. Multimodal integration of MCG with 3D rendering of the patient's heart from CT or MR images is useful to characterize several kinds of arrhythmogenic mechanisms, such as accessory pathways, atrial or ventricular ectopic foci [8][9][10], different types of reentry in patients with atrial flutter or fibrillation [13][14][15][16]. MCG is useful to define the stability of the arrhythmogenic substrate and to plan the most appropriate interventional approach.…”
Section: Discussionmentioning
confidence: 99%
“…We have previously evaluated the accuracy of MCG localization of cardiac sources experimentally [10], [11] and in clinical studies [14], [15], using simple models such as ECD and EMD. However, in the physiological reality, multiple current sources are simultaneously activated during almost all the cardiac cycle.…”
Section: Discussionmentioning
confidence: 99%
“…Our most recent results with MCG-based 3D electroanatomical imaging have been described elsewhere [14], [15]. However an example of pre-ablation imaging of a right-sided Kent-type accessory pathway in a patients with the Wolff-Parkinson-White syndrome is given in Fig.…”
Section: A Mcg-based 3d Electroanatomical Imagingmentioning
confidence: 94%