2022
DOI: 10.1016/j.talanta.2022.123285
|View full text |Cite
|
Sign up to set email alerts
|

Non-targeted analysis of unknown volatile components in scented stationery via headspace GC-Orbitrap MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 19 publications
0
4
0
Order By: Relevance
“…Separations were performed on a weak polar HP-5 MS column (30 m × 0.25 mm × 0.25 μm) (Agilent Technologies, California, USA) using the following temperature program: 40 °C (held for 1 min) and 5 °C/min to 160 °C and then 20 °C/min to 250 °C (held for 5 min). This instrumental condition has been maturely applied in our previous studies on nontarget analysis. , …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Separations were performed on a weak polar HP-5 MS column (30 m × 0.25 mm × 0.25 μm) (Agilent Technologies, California, USA) using the following temperature program: 40 °C (held for 1 min) and 5 °C/min to 160 °C and then 20 °C/min to 250 °C (held for 5 min). This instrumental condition has been maturely applied in our previous studies on nontarget analysis. , …”
Section: Methodsmentioning
confidence: 99%
“…This instrumental condition has been maturely applied in our previous studies on nontarget analysis. 38,39 MS acquisition with full scan mode was conducted at an m/z range of 40−500. Each sample was analyzed in both the EI mode and CI mode.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…Environmental chemicals have been identified using NTA in other unclassified consumer products such as stationary [ 85 ], clothing [ 86 ], personal care products [ 87 ], and tobacco products [ 88 ]. Phillips et al utilized a broad sampling scheme to identify environmental chemicals in a wide variety of consumer products [ 4 ].…”
Section: Characterization Of Exposure Sources Using Ntamentioning
confidence: 99%
“…The chemiluminescence sulfur detector lacks a high detection sensitivity on sulfur compounds, whereas sulfur compounds analyzed by a pulsed flame photometric detector can only be measured under a limited concentration range [ 11 , 12 ]. Gas chromatography–Orbitrap–mass spectrometry (GC-Orbitrap-MS) has gained much attention in identifying and quantifying trace volatiles in the food science area since Orbitrap-MS possesses a better mass accuracy and relative ion abundance consistency under a wide concentration range of sulfur volatiles [ 13 , 14 ]. Therefore, GC-Orbitrap-MS and GC-quadrupole mass spectrometry (GC-qMS) were used in the present study for the analysis of sulfur volatiles and other volatile compounds in passion fruit wine, respectively.…”
Section: Introductionmentioning
confidence: 99%