2021
DOI: 10.1016/j.chroma.2021.462154
|View full text |Cite
|
Sign up to set email alerts
|

Non-target bioanalytical eight-dimensional hyphenation including bioassay, heart-cut trapping, online desalting, orthogonal separations and mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
19
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 36 publications
(20 citation statements)
references
References 36 publications
0
19
0
1
Order By: Relevance
“…Hence, zones of interest were heart-cut eluted directly out of the bioassay plate and transferred through an online desalting device to RP-HPLC−DAD−HESI-MS. This reduced the interfering salts and nutrients from the bioassay, separated possibly coeluting substances via the orthogonal chromatographic system, and added value via spectral and mass spectrometric data ( Schreiner and Morlock, 2021 ). Through this straightforward comprehensive workflow, the 60 most bioactive compounds in the botanicals were assigned ( Table 2 ).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Hence, zones of interest were heart-cut eluted directly out of the bioassay plate and transferred through an online desalting device to RP-HPLC−DAD−HESI-MS. This reduced the interfering salts and nutrients from the bioassay, separated possibly coeluting substances via the orthogonal chromatographic system, and added value via spectral and mass spectrometric data ( Schreiner and Morlock, 2021 ). Through this straightforward comprehensive workflow, the 60 most bioactive compounds in the botanicals were assigned ( Table 2 ).…”
Section: Resultsmentioning
confidence: 99%
“…The MS was operated in polarity-switching mode, while the ESI probe was heated to 600°C and ESI source to 120°C. The sampling frequency was set to 5 Hz and cone voltage to ±10 V in both ionization modes ( Schreiner and Morlock, 2021 ). The MassLynx V4.2 software (Waters) was used to evaluate and process the data.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A recently developed 8D hyphenation ( Schreiner and Morlock 2021 ) was alternatively used to further characterize the hormonal-effective compound zones. This hyphenation allowed eluting the bioactive zone from the bioautogram into the second separation and photodiode array (PDA) detection dimension (RP-HPLC-PDA-HESI-MS).…”
Section: Resultsmentioning
confidence: 99%
“…According to the latest workflow ( Schreiner and Morlock 2021 ) bioactive zones were eluted (TLC-MS Interface, CAMAG) with 10% aqueous methanol (MS-grade, Honeywell, Morristown, NJ, USA) provided by a standalone pump (515 HPLC pump, Waters, Eschborn, Germany) at a flow rate of 0.1 mL/min. The eluted zone was transferred through a biocompatible inline-filter (IDEX Health & Science, Oak Harbor, WA, USA) containing a PEEK frit (0.5 μm, Techlab, Braunschweig, Germany) to a two-position switching-valve (MXT-Series PD715-000, Rheodyne IDEX Health & Science), where the analytes were trapped on a defender guard/pre-column (Accucore RP-MS, 10 mm × 2.1 mm, 2.6 μm, Thermo Scientific, Bellefonte, PA, USA).…”
Section: Methodsmentioning
confidence: 99%