2020
DOI: 10.1016/j.apenergy.2020.114604
|View full text |Cite
|
Sign up to set email alerts
|

Non-isothermal carbothermic reduction kinetics of calcium ferrite and hematite as oxygen carriers for chemical looping gasification applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 20 publications
(7 citation statements)
references
References 51 publications
0
7
0
Order By: Relevance
“…The schematic diagram of the thermo-gravimetric analyzer is similar to that of the previous study. 12 , 22 25 The reacted gas in the thermo-gravimetric analyzer was blown into a quadrupole mass spectrometer (TILON LC-D200, AMETEK LLC, USA) to detect its components according to the molecular weight. The electron ionization voltage, the temperature of the transfer line, and the m / z range of the mass spectrometer are 10–70 eV, 270 °C, and 1–200, respectively.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The schematic diagram of the thermo-gravimetric analyzer is similar to that of the previous study. 12 , 22 25 The reacted gas in the thermo-gravimetric analyzer was blown into a quadrupole mass spectrometer (TILON LC-D200, AMETEK LLC, USA) to detect its components according to the molecular weight. The electron ionization voltage, the temperature of the transfer line, and the m / z range of the mass spectrometer are 10–70 eV, 270 °C, and 1–200, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The pyrolysis of pyrite was carried out in a thermo-gravimetric analyzer (Setaram Evo TG-DTA 1750) consisting of a vertical furnace, a gas manometer system for controlling the atmosphere in the reactor, and an electronic balance connected to a computer that records the mass loss. The schematic diagram of the thermo-gravimetric analyzer is similar to that of the previous study. , The reacted gas in the thermo-gravimetric analyzer was blown into a quadrupole mass spectrometer (TILON LC-D200, AMETEK LLC, USA) to detect its components according to the molecular weight. The electron ionization voltage, the temperature of the transfer line, and the m / z range of the mass spectrometer are 10–70 eV, 270 °C, and 1–200, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…CFs are acknowledged as superior bonding phases in fluxed sinters with relatively high compressive strength. In this study, the compressive strength of the CF sample synthesized by solid-state sintering 33 was tested (SANS CMT-5150) and compared with that of AT. The samples were first heated from room temperature to 1573 K, held for 1 h in an alumina crucible, and then cooled under an air atmosphere.…”
Section: Compressive Strengthmentioning
confidence: 99%
“…Moreover, the reduction behavior of calcium ferrite minerals under CO and H 2 were also investigated. [7][8][9][10][11][12] In addition, in recent research, it has been widely applied including as a thermal catalyst for decreasing the NOx emission in the sintering process, [13][14][15] as a photocatalytic for degradation of the organic wastewater 16,17) and volatile organic compounds, [18][19][20] as a photocathode for producing hydrogen in water splitting, [21][22][23] as a oxygen carrier for chemical looping gasification applications, [24][25][26][27][28] as a anode material for lithiumion batteries 29) and as a visible light activated gas sensor. 30) The surface structure of calcium ferrite affects the strength of sinter and reduction reaction of it with CO and H 2 in the blast furnace.…”
Section: Introductionmentioning
confidence: 99%