Non-invasive real-time imaging of atherosclerosis in mice using ultrasound biomicroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
48
0
4

Year Published

2008
2008
2023
2023

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 62 publications
(57 citation statements)
references
References 13 publications
2
48
0
4
Order By: Relevance
“…6 UBM measurements of IMT and plaque thickness in various animal studies have been compared with histological data showing close correlations between the methods. 7,8 Moreover, we have published the results of in vitro measurements of IT and MT of human mesenteric arteries by UBM, demonstrating close correlations to histological measurements. 9 In that study the discrimination capacity of UBM was tested with silicon layer phantoms (measuring 1-200 μm) showing high accuracy.…”
Section: Introductionmentioning
confidence: 58%
“…6 UBM measurements of IMT and plaque thickness in various animal studies have been compared with histological data showing close correlations between the methods. 7,8 Moreover, we have published the results of in vitro measurements of IT and MT of human mesenteric arteries by UBM, demonstrating close correlations to histological measurements. 9 In that study the discrimination capacity of UBM was tested with silicon layer phantoms (measuring 1-200 μm) showing high accuracy.…”
Section: Introductionmentioning
confidence: 58%
“…Before the diet was started and after 4, 8, 12, and 16 wk of treatment, a UBM (Vevo 770, version 2.2.2, Visualsonics, Toronto, Canada) with a transducer frequency of 40 MHz (providing a theoretical resolution of 40 m at a frame rate of 32 Hz) was used for vascular imaging. The brachiocephalic artery and ascending aorta were visualized in two different projections, a longaxis view and a cross-sectional short-axis view in line with previously published protocol (16). According to the published data, for measurements of aortic intima media thickness, intra-and interobserver variability are 4.7% and 6.7%, respectively.…”
Section: Methodsmentioning
confidence: 95%
“…Using a high-resolution ultrasound biomicroscope (UBM), we are now able to follow mouse atherosclerotic plaque growth over time in a noninvasive manner (16). In addition, mouse coronary artery function can be studied in vivo using colorDoppler echocardiography using a recently developed protocol (52).…”
mentioning
confidence: 99%
“…Although experimental atherosclerosis can be assessed using advanced imaging techniques such as angiography, Doppler ultrasound, B-mode ultrasound and magnetic resonance (30)(31)(32), the main methods employed in the quantification of mouse atherosclerosis are those mentioned in this brief review.…”
Section: Methods Choicementioning