2024
DOI: 10.1089/neu.2023.0001
|View full text |Cite
|
Sign up to set email alerts
|

Non-Invasive Methods for Intracranial Pressure Monitoring in Traumatic Brain Injury Using Transcranial Doppler: A Scoping Review

Karol Martínez-Palacios,
Sebastián Vásquez-García,
Olubunmi A. Fariyike
et al.
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 52 publications
0
2
0
Order By: Relevance
“…The IMPRESSIT-2 study, a prospective multicenter unblinded clinical trial, compared the use of TCD waveform analysis to invasive ICP in detecting elevated ICP; it demonstrated a high negative predictive value of TCP-derived measures in ruling out ICP elevation > 20 mmHg, indicating a high discriminant accuracy for excluding elevated ICP but a very low positive predictive values [13 && ]. Limitations of TCD for noninvasive ICP monitoring include challenges in obtaining reliable insonation windows in almost one third of patients, specialized expertise required to analyze and interpret TCD waveforms, and the episodic nature of data acquisition which reduces the likelihood of capturing significant events or trends [14].…”
Section: Key Pointsmentioning
confidence: 99%
“…The IMPRESSIT-2 study, a prospective multicenter unblinded clinical trial, compared the use of TCD waveform analysis to invasive ICP in detecting elevated ICP; it demonstrated a high negative predictive value of TCP-derived measures in ruling out ICP elevation > 20 mmHg, indicating a high discriminant accuracy for excluding elevated ICP but a very low positive predictive values [13 && ]. Limitations of TCD for noninvasive ICP monitoring include challenges in obtaining reliable insonation windows in almost one third of patients, specialized expertise required to analyze and interpret TCD waveforms, and the episodic nature of data acquisition which reduces the likelihood of capturing significant events or trends [14].…”
Section: Key Pointsmentioning
confidence: 99%
“…However, on the other hand, this sensor cannot be recalibrated after placement, and although the insertion stage is very accurate, the measured value will drift to a certain extent over time ( Al-Tamimi et al, 2009 ). Noninvasive ICP estimation methods such as optic nerve sheath diameter measurement ( Tian et al, 2023 ), transcranial Doppler (TCD) measurement of blood flow velocity and automated pupillometry are increasingly used in the field of noninvasive ICP measurement ( Giede-Jeppe et al, 2021 ; Martínez-Palacios et al, 2023 ). However, due to the high specificity between researchers and study populations, such methods require standardized training for operators.…”
Section: Introductionmentioning
confidence: 99%