2018
DOI: 10.1016/j.jogoh.2018.08.009
|View full text |Cite
|
Sign up to set email alerts
|

Non-invasive fetal monitoring using electrocardiography and phonocardiography: A preliminary study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(16 citation statements)
references
References 9 publications
0
15
0
Order By: Relevance
“…Ten of the 43 studies were from the UK [25][26][27]35,[37][38][39]49,50,55], 22 from other European countries [24,[28][29][30][31][32][33]36,40,[42][43][44]48,[51][52][53][54]56,57,61,64,65], five from Japan [41,59,60,62,63], one from India [45], one from Australia [66], three from the United States of America (USA) [46,47,58], and one study from both the Netherlands and USA [34]. The included studies were heterogeneous, they had a median sample size of 34.5 participants (range 1-657) and a median number of recordings of 63 (range 1-657).…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Ten of the 43 studies were from the UK [25][26][27]35,[37][38][39]49,50,55], 22 from other European countries [24,[28][29][30][31][32][33]36,40,[42][43][44]48,[51][52][53][54]56,57,61,64,65], five from Japan [41,59,60,62,63], one from India [45], one from Australia [66], three from the United States of America (USA) [46,47,58], and one study from both the Netherlands and USA [34]. The included studies were heterogeneous, they had a median sample size of 34.5 participants (range 1-657) and a median number of recordings of 63 (range 1-657).…”
Section: Resultsmentioning
confidence: 99%
“…Two studies used only fPCG devices, of which one was named the Fetaphon-2000 [42] and the other was unnamed [45]. Three studies investigated both fECG and fPCG devices, all of which were unnamed [32,37,41]. The remaining study used a combined fECG/fPCG device named the Invu system [46].…”
Section: Fhr Devicesmentioning
confidence: 99%
See 2 more Smart Citations
“…Li et al [38] showed that this task can be achieved by IVA, in a suboptimal "mismodeling" approach [30]. Given the ongoing interest in non-invasive methods for fetal monitoring, in multi-subject and multimodal setups (see, e.g., [39] and references therein), JISA is a potentially useful candidate to address some of these challenges. Our preliminary experimental results on the ECG data of [32], using an approach similar to that in [38], indicate that the fetal electrocardiogram (FECG) can be extracted to a reasonable extent even by the simplest JISA model that we consider in this paper, using the algorithm in [11].…”
Section: Introductionmentioning
confidence: 99%