2006
DOI: 10.1016/j.compbiomed.2005.06.001
|View full text |Cite
|
Sign up to set email alerts
|

Non-invasive beat-to-beat cardiac output monitoring by an improved method of transthoracic bioimpedance measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
159
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 201 publications
(160 citation statements)
references
References 19 publications
1
159
0
Order By: Relevance
“…These BP values were automatically and continuously corrected to oscillometric BP values obtained at the contralateral arm (brachial artery). An estimate of real-time beat-to-beat SV was derived using an improved method of transthoracic impedance cardiography (ICG) (15,16,18). ICG utilizes changes in thoracic electrical impedance to estimate changes in blood volume in the aorta and changes in fluid volume in the thorax (16).…”
Section: Methodsmentioning
confidence: 99%
“…These BP values were automatically and continuously corrected to oscillometric BP values obtained at the contralateral arm (brachial artery). An estimate of real-time beat-to-beat SV was derived using an improved method of transthoracic impedance cardiography (ICG) (15,16,18). ICG utilizes changes in thoracic electrical impedance to estimate changes in blood volume in the aorta and changes in fluid volume in the thorax (16).…”
Section: Methodsmentioning
confidence: 99%
“…The method is based on concentrically interlocking control loops for correct long-term tracing of finger BP and delivers, in contrast to intermittent set point re-adjustments of the conventional vascular unloading technique, BP without interruptions (Fortin et al, 2006a). For thoracic impedance measurement, three CNSystems shortband electrodes (two electrode bands set at a predefined distance onto a common adhesive medium; sampling rate = 500 Hz, I eff < 400 A, f = 45 kHz, Z0,range = 10-75 , dZ/dt = ±10 /s) were placed onto the participant: one placed at the nape of the neck close to the glottis, two others placed on the thorax close to the xiphoid (see Fortin et al, 2006b). …”
Section: Physiological Recordingmentioning
confidence: 99%
“…An increase or a decrease of beat-to-beat RR-interval and SBP in the same direction for at least three cardiac cycles was used to describe the steepness of the regression line [12].…”
Section: Heart Rate and Blood Pressure Variabilitymentioning
confidence: 99%
“…TFM s ECG/impedance electrodes were positioned at the neck and thoracic regions, the latter at the midclavicular line at the xiphoid process level [12]. TPR was calculated as mean arterial blood pressure/ cardiac output and mean arterial pressure from (SBP-DBP)/3)þDBP.…”
Section: Hemodynamic Monitoringmentioning
confidence: 99%
See 1 more Smart Citation