2007
DOI: 10.1016/j.echo.2006.08.023
|View full text |Cite
|
Sign up to set email alerts
|

Non-Doppler Two-dimensional Strain Imaging by Echocardiography–From Technical Considerations to Clinical Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
386
0
11

Year Published

2009
2009
2022
2022

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 449 publications
(400 citation statements)
references
References 28 publications
3
386
0
11
Order By: Relevance
“…6,7 In these patients, there are 2 potential explanations, not mutually exclusive, for a new major coronary event, namely, progression of atherosclerotic disease in native arteries or the development of vascular disease in the grafts. Previous authors of an angiography study reported 8% venous graft failure at 1 year, 38% at 5 years, and 75% at 10 years after surgery, 8 and progression of the atherosclerotic process in up to 51% 15 years after CABG. 9 The prognosis of this subset of patients, nevertheless, remains doubtful.…”
Section: Introductionmentioning
confidence: 93%
“…6,7 In these patients, there are 2 potential explanations, not mutually exclusive, for a new major coronary event, namely, progression of atherosclerotic disease in native arteries or the development of vascular disease in the grafts. Previous authors of an angiography study reported 8% venous graft failure at 1 year, 38% at 5 years, and 75% at 10 years after surgery, 8 and progression of the atherosclerotic process in up to 51% 15 years after CABG. 9 The prognosis of this subset of patients, nevertheless, remains doubtful.…”
Section: Introductionmentioning
confidence: 93%
“…Too low frame rate results in excessive displacement of the speckles between the frames, and too high frame rate is associated with high levels of noise. The optimal frame rate for 2D speckle tracking is 50-70 frames per second (FPS) (67,68,71).…”
Section: Strain Imaging By Speckle Trackingmentioning
confidence: 99%
“…С появлением ультразвуковой технологии 2D-стрейн (speckle tracking), основанной на опреде-лении скорости движения миокарда при помощи отслеживания перемещения естественных акустиче-ских маркеров на стандартном эхокардиографиче-ском (ЭхоКГ) изображении в В-режиме, стало воз-можным изучение глобальной и регионарной сокра-тимости миокарда [3]. Благодаря технологии 2D-стрейн стало возможным изучение показателей деформации миокарда, апикальной и базальной рота-ции, скручивания и раскручивания ЛЖ, что позво-ляет по-новому оценивать физиологию сокращения и расслабления миокарда.…”
Section: Discussionunclassified