2022
DOI: 10.1136/jnis-2022-018901
|View full text |Cite
|
Sign up to set email alerts
|

Non-contrast enhanced silent MR angiography to evaluate hemodynamics and morphology of unruptured intracranial aneurysms: a comparative computational fluid dynamics study

Abstract: BackgroundSilent MR angiography (silent MRA) is a new generation of non-contrast enhanced angiography with outstanding advantages in visualizing cerebrovascular lesions and the follow-up after endovascular treatment for intracranial aneurysms (IAs). This study aims to investigate the reliability of silent MRA-based three-dimensional (3D) geometric description and hemodynamic calculation of IAs.Methods19 patients with 23 unruptured IAs, who underwent both silent MRA and 3D rotational angiography (3DRA), were in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 29 publications
0
2
0
Order By: Relevance
“…The procedure using MIMICS 21.0 software (Materialise NV, Leuven, Belgium) unfolds as follows: Data are imported via “New Project,” settings are adjusted through “Threshold” until blood vessels are distinctly displayed, the region of interest is selected in “Crop Mask” for 3D image reconstruction, and the resultant file is exported in STereoLithography (STL) format. AneuFlow™ software (V1.1.4.1, ArteryFlow Technology, Hangzhou, China) for measuring aneurysm morphology and hemodynamics encompasses three steps ( 18 ). First, the STL file is imported into the AneuFlow™ software, allowing doctors to obtain additional morphological parameters by manually identifying the aneurysm neck.…”
Section: Methodsmentioning
confidence: 99%
“…The procedure using MIMICS 21.0 software (Materialise NV, Leuven, Belgium) unfolds as follows: Data are imported via “New Project,” settings are adjusted through “Threshold” until blood vessels are distinctly displayed, the region of interest is selected in “Crop Mask” for 3D image reconstruction, and the resultant file is exported in STereoLithography (STL) format. AneuFlow™ software (V1.1.4.1, ArteryFlow Technology, Hangzhou, China) for measuring aneurysm morphology and hemodynamics encompasses three steps ( 18 ). First, the STL file is imported into the AneuFlow™ software, allowing doctors to obtain additional morphological parameters by manually identifying the aneurysm neck.…”
Section: Methodsmentioning
confidence: 99%
“…Briefly, DICOM images were segmented in the region of interest, including aneurysm sac and adjacent parent vessels. Then eight morphological parameters ( 20 , 21 ) were measured and calculated using AneuFlowTM (ArteryFlow, Hangzhou) ( 22 ), including H max , SR, AR, θ F , θ A , EI, NSI, UI. As for CFD models, finite volume meshes with 0.5–1 million elements were imported into the CFD solver to calculate time-resolved 3D velocity and pressure fields.…”
Section: Methodsmentioning
confidence: 99%