Non-Adaptive Methods for Fetal ECG Signal Processing: A Review and Appraisal

Abstract: Fetal electrocardiography is among the most promising methods of modern electronic fetal monitoring. However, before they can be fully deployed in the clinical practice as a gold standard, the challenges associated with the signal quality must be solved. During the last two decades, a great amount of articles dealing with improving the quality of the fetal electrocardiogram signal acquired from the abdominal recordings have been introduced. This article aims to present an extensive literature survey of differe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
45
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 63 publications
(48 citation statements)
references
References 100 publications
0
45
0
1
Order By: Relevance
“…Within the field of signal processing, studies include a review of biomedical signal and image processing for biomedical engineering and clinical procedures [38] and works focused on specific types of biomedical signals: for example, EEG [39], ECG [40], and EMG [41].…”
Section: Related Workmentioning
confidence: 99%
“…Within the field of signal processing, studies include a review of biomedical signal and image processing for biomedical engineering and clinical procedures [38] and works focused on specific types of biomedical signals: for example, EEG [39], ECG [40], and EMG [41].…”
Section: Related Workmentioning
confidence: 99%
“…The value of this error estimates the usefulness of the FHR signal for assessing the clinically important fetal heart rate variability from beat to beat. The last step of the research should be the evaluation whether an FECG morphology analysis (assessment of the amplitude-time relationship between particular waves) is feasible as this provides completely new diagnostic information helpful for verifying the true fetal distress in cases of a recognized suspected or abnormal FHR signal 33,54,57,58 .…”
Section: Technical Validationmentioning
confidence: 99%
“…The M G and M B quantities were calculated from formulas (12) and (34), while N G and N B from formulas (38) - (41).…”
Section: Resultsmentioning
confidence: 99%
“…It would also be good to combine bioelectrical impedance spectroscopy with other measurement methods such as ECG or EEG [40]- [42]. Except measuring body structure, it would be also possible to detect stress or some serious conditions [10], [41]. Potential implementation of impedance in medicine is related with fact that it reflects also the change in blood pressure, and that the obtained results are very accurate [10].…”
Section: A Further Research Plansmentioning
confidence: 99%