2019
DOI: 10.1093/annweh/wxz003
|View full text |Cite
|
Sign up to set email alerts
|

Nitrous Oxide Exposure Among Dental Personnel and Comparison of Active and Passive Sampling Techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…Passive samplers, which rely on less invasive technologies such as adsorbent strips and wearables like silicone wristbands, pouches, and badges, provide an alternative strategy to screen for both known and unknown exposures in large populations. PSDs validated for exposures with known uptake rates, such as benzene or trichloroethylene, have been widely used in occupational monitoring studies for industrial chemicals [23,[48][49][50][51][52][53][54]. However, for most PSDs, ongoing research is focused on better understanding the mechanisms for chemical equilibrium with sampler matrices, which can vary by chemical molecular weight, media pore size, and silicone/air partitioning coefficients [55].…”
Section: Measuring the External Exposomementioning
confidence: 99%
“…Passive samplers, which rely on less invasive technologies such as adsorbent strips and wearables like silicone wristbands, pouches, and badges, provide an alternative strategy to screen for both known and unknown exposures in large populations. PSDs validated for exposures with known uptake rates, such as benzene or trichloroethylene, have been widely used in occupational monitoring studies for industrial chemicals [23,[48][49][50][51][52][53][54]. However, for most PSDs, ongoing research is focused on better understanding the mechanisms for chemical equilibrium with sampler matrices, which can vary by chemical molecular weight, media pore size, and silicone/air partitioning coefficients [55].…”
Section: Measuring the External Exposomementioning
confidence: 99%
“…The results of this review outlined that this technique was only used in a few studies [5,51,61,62]. The IR presents some limitations, such as the need to guarantee an adequate instrumental warm-up time before starting the measurement, sensitivity to pressure differences, which must accounted for, and interference with CO 2 and water vapor [63].…”
Section: Real-time Monitoringmentioning
confidence: 99%
“…Passive or diffusive sampling requires a longer sampling time than the active sampling to collect the same amount of analyte, but is characterized by ease of use and cheapness [63,71]. Specifically, the SKC VOC-Check, 3M 3500, Draeger Orsa 5, Zambelli TK200 and ISC Maugeri Radiello ® were used in the reviewed literature.…”
Section: Time-integrated Samplingmentioning
confidence: 99%