Nitrogen-doped carbon quantum dots as a “turn off-on” fluorescence sensor based on the redox reaction mechanism for the sensitive detection of dopamine and alpha lipoic acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 37 publications
(13 citation statements)
references
References 47 publications
0
13
0
Order By: Relevance
“…The HRTEM shown in the Figure S1A inset indicates that B,N-CQDs has a lattice spacing of 0.208 nm matching with that of (100) facet of graphite. , The XRD patterns show a broad band centered at 24° matching with that of the (002) facet of carbon-based material, indicating that B,N-CQDs have highly disordered carbon atoms (Figure S1C). ,,, XPS and FTIR characterizations were performed to analyze the components, surface groups, and structure of B,N-CQDs. The FTIR spectrum of B,N-CQDs shows that a peak of O–H/N–H stretching vibrations appears at 3448 cm –1 with a broad band.…”
Section: Resultsmentioning
confidence: 99%
“…The HRTEM shown in the Figure S1A inset indicates that B,N-CQDs has a lattice spacing of 0.208 nm matching with that of (100) facet of graphite. , The XRD patterns show a broad band centered at 24° matching with that of the (002) facet of carbon-based material, indicating that B,N-CQDs have highly disordered carbon atoms (Figure S1C). ,,, XPS and FTIR characterizations were performed to analyze the components, surface groups, and structure of B,N-CQDs. The FTIR spectrum of B,N-CQDs shows that a peak of O–H/N–H stretching vibrations appears at 3448 cm –1 with a broad band.…”
Section: Resultsmentioning
confidence: 99%
“…Zhang et al [ 148 ] developed the first method resorting to spectroscopy to analyze alpha-lipoic acid (ALA) in real samples. This methodology was also used to determine dopamine (DA).…”
Section: Applicationsmentioning
confidence: 99%
“…Despite such evidence of the excellent operational efficiency of various stimuli-responsive polymer spacers, a similar redox-responsive PL switchable gold-QD system is so far not reported to the best of our knowledge. Notably, the ongoing development of redox-active systems is highly desirable in view of the growing demand for investigation of biological phenomena, e,g ., detecting enzymatic activity, maltose biosensing, dopamine, , and alpha lipoic acid …”
Section: Introductionmentioning