2011
DOI: 10.1007/s12665-011-1456-3
|View full text |Cite
|
Sign up to set email alerts
|

Nitric oxide emissions from soils: a case study with temperate soils from Saxony, Germany

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 31 publications
0
7
0
Order By: Relevance
“…Correlation analysis N 2 O emission was significantly and positively correlated with Tmax, Tmin, Tmean, WFPS, CO 2 and Mineral N (r= 0.5549, 0.5241, 0.7729, 0.8345, 0.8262, 0.8507, respectively, p<0.01; Table 3). Temperature, radiation and mineral N have been shown to increase soil microbial activity and decomposition of organic matter, which influences N 2 O emission (Oertel et al, 2012 ). The arid climate of Griffith and sandy loam texture of the soil contribute to high water loss though evaporation or infiltration.…”
Section: Resultsmentioning
confidence: 99%
“…Correlation analysis N 2 O emission was significantly and positively correlated with Tmax, Tmin, Tmean, WFPS, CO 2 and Mineral N (r= 0.5549, 0.5241, 0.7729, 0.8345, 0.8262, 0.8507, respectively, p<0.01; Table 3). Temperature, radiation and mineral N have been shown to increase soil microbial activity and decomposition of organic matter, which influences N 2 O emission (Oertel et al, 2012 ). The arid climate of Griffith and sandy loam texture of the soil contribute to high water loss though evaporation or infiltration.…”
Section: Resultsmentioning
confidence: 99%
“…Gas sampling was performed at 7–10‐day intervals at each subplot based on the GHG sampling protocol of GRACEnet Chamber‐based Trace Gas Flux Measurement (Parkin & Venterea, 2010; Tenesaca & Al‐Kaisi, 2015). In this sense, the well‐known static closed chamber method was used to measure CO 2 emissions (Oertel et al, 2012).…”
Section: Methodsmentioning
confidence: 99%
“…The N 2 O emissions were measured using the sampling protocol of GRACEnet Chamber-based Trace Gas Flux Measurement (Parkin & Venterea, 2010). The samples were collected in both fields (CT and NT) for 7 to 10 days intervals and every 2 weeks (during wintertime) using the static closed chamber method (Oertel et al, 2012). The chamber was 12.5 cm high and had a diameter of 15 cm constructed on polyvinyl chloride (PVC).…”
Section: N 2 O Emissions Measurementmentioning
confidence: 99%