2018
DOI: 10.1007/s00117-018-0451-z
|View full text |Cite
|
Sign up to set email alerts
|

Nierenfunktionsdiagnostik mittels Magnetresonanztomographie

Abstract: Due to progress in the development of sequences and techniques magnetic resonance imaging (MRI) methods, such as functional MR urography (fMRU), arterial spin labeling (ASL), diffusion-weighted imaging (DWI), diffusion tension imaging (DTI) and blood oxygen level dependent MRI (BOLD-MRI) have become available for renal functional evaluation. In recent years research of these imaging techniques has demonstrated that they provide valid functional data with respect to renal perfusion, oxygenation and interstitial… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
3

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 34 publications
0
4
0
3
Order By: Relevance
“…Following the dynamic contrast-enhanced series, additional scans may be needed in the case of delayed or absent contrast excretion. In the case of absent or minimal dilation of the urinary tract, high-resolution T1-weighted 3D anatomical sequences are needed near the end of the examination in order to evaluate the exact course of the contrast-enhanced ureters [2].…”
Section: Preparing the Examinationmentioning
confidence: 99%
See 4 more Smart Citations
“…Following the dynamic contrast-enhanced series, additional scans may be needed in the case of delayed or absent contrast excretion. In the case of absent or minimal dilation of the urinary tract, high-resolution T1-weighted 3D anatomical sequences are needed near the end of the examination in order to evaluate the exact course of the contrast-enhanced ureters [2].…”
Section: Preparing the Examinationmentioning
confidence: 99%
“…"MR-Urography V5.0 Plugin for ImageJ" from Quant-IF-Labs at the University Rouen (CHU, France) [14] and "CHOP-fMRU v1.2.52" from the Childrenʼs Hospital of Philadelphia (USA) [15] are two programs for children with good agreement at least regarding relevant obstructions in comparative studies [16]. The evaluation of functional data with the semi-automate CHOP software has been performed many times and has become established [2]. This software is used as an example in the following.…”
Section: Determination Of Functional Parametersmentioning
confidence: 99%
See 3 more Smart Citations