2015
DOI: 10.11159/ijtan.2015.004
|View full text |Cite
|
Sign up to set email alerts
|

Ni-doped Carbon Nanofilaments (Ni-CNF): Preparation and Use as Reforming Catalyst

Abstract: -

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2015
2015
2015
2015

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 33 publications
(34 reference statements)
0
3
0
Order By: Relevance
“…On a 17-g steel strip with dimensions of 413 mm × 25 mm × 0.5 mm, some 0.3 g/min of liquid C 2 H 5 OH was reacted with CO 2 at a flow rate of 160 SCCM (or 2.67 × 10 −6 Nm 3 .s −1 ) at room temperature and barometric pressure (25 °C, 1 atm), and the reaction was left to proceed for about 4−6 h. 27 The resulting CNFs, deposited as C according to eq 8, were harvested and then functionalized by acid-activation using dilute 4 M HNO 3 where 250 mL of 68% (15.8 M) concentrated acid was dissolved in a liter of solution using distilled H 2 O. About 50 g of the CNFs were refluxed with 4 M HNO 3 at 95 °C for 3 h. 28…”
Section: Experimental Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…On a 17-g steel strip with dimensions of 413 mm × 25 mm × 0.5 mm, some 0.3 g/min of liquid C 2 H 5 OH was reacted with CO 2 at a flow rate of 160 SCCM (or 2.67 × 10 −6 Nm 3 .s −1 ) at room temperature and barometric pressure (25 °C, 1 atm), and the reaction was left to proceed for about 4−6 h. 27 The resulting CNFs, deposited as C according to eq 8, were harvested and then functionalized by acid-activation using dilute 4 M HNO 3 where 250 mL of 68% (15.8 M) concentrated acid was dissolved in a liter of solution using distilled H 2 O. About 50 g of the CNFs were refluxed with 4 M HNO 3 at 95 °C for 3 h. 28…”
Section: Experimental Methodsmentioning
confidence: 99%
“…The resulting CNFs, deposited as C according to , were harvested and then functionalized by acid-activation using dilute 4 M HNO 3 where 250 mL of 68% (15.8 M) concentrated acid was dissolved in a liter of solution using distilled H 2 O. About 50 g of the CNFs were refluxed with 4 M HNO 3 at 95 °C for 3 h …”
Section: Experimental Methodsmentioning
confidence: 99%
“…Different conditions (contact time, acid concentration, and temperature) were prescreened to ascertain appropriate acid treatment. Nitric acid concentration of 10 M with contact time of 5 h was chosen after optimization based on already-reported work on those nanofilaments by Abatzoglou et al 26 In these conditions, CNF were not broken or degraded, and most of the metal added in the following step was attached to them. However, the effect of acid treatment temperature has to be understood.…”
Section: Resultsmentioning
confidence: 99%