2015
DOI: 10.1016/bs.mie.2015.04.013
|View full text |Cite
|
Sign up to set email alerts
|

Next-Generation AUC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 36 publications
(23 citation statements)
references
References 20 publications
0
23
0
Order By: Relevance
“…In addition, slow calculations and lack of parallelization capabilities in Sedfit make this method impractical for the analysis of MWL data available from the new generation of AUC. 8, 18, 32, 33 …”
Section: Resultsmentioning
confidence: 99%
“…In addition, slow calculations and lack of parallelization capabilities in Sedfit make this method impractical for the analysis of MWL data available from the new generation of AUC. 8, 18, 32, 33 …”
Section: Resultsmentioning
confidence: 99%
“…As shown recently, MWL analysis can provide access to hydrodynamic and optical properties simultaneously by means of sedimentation velocity data. 5,10,12 For gold nanorods it was demonstrated that MWL-AUC can give rise to the size and shape dependent optical properties using speed ramp experiments. 5 However, quantitative information was not yet accessible.…”
Section: Determination Of Size Dependent Optical Properties Of Gold Npsmentioning
confidence: 99%
“…Hence, the development of new evaluation procedures and respective software capable of MWL-analysis is highly attractive for two reasons: First, it will allow for a direct correlation of hydrodynamic and optical properties even in complex mixtures as it was recently developed for sedimentation velocity data. 10,12 In contrast to sedimentation velocity experiments typically conducted at a constant speed or a series of discrete increasing rotor speeds, speed ramp experiments offer a much higher dynamic range. The capability to qualitatively distinguish between different species of gold nanorods has been recently shown.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…SV data were analyzed with UltraScan-III [40] All calculations were performed on the XSEDE UltraScan Science Gateway using high-performance computing resources at the Texas Advanced Computing Center, at the San Diego Supercomputing Center, and at the Bioinformatics Core Facility at the University of Texas Health Science Center at San Antonio. All measurements were made in 20 mM sodium phosphate buffer, pH 7.8, supplemented with 0.15 M or 0.3 mM NaCl.…”
Section: Methodsmentioning
confidence: 99%