2004
DOI: 10.1016/j.jchromb.2003.11.042
|View full text |Cite
|
Sign up to set email alerts
|

New trend in sample preparation: on-line microextraction in packed syringe for liquid and gas chromatography applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
94
0
4

Year Published

2009
2009
2019
2019

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 355 publications
(100 citation statements)
references
References 14 publications
2
94
0
4
Order By: Relevance
“…Any sorbent material such as silica-based (C2, C8, C18), strong cation exchanger (SCX) using sulfonic acid-bonded silica, restricted access material, HILIC, carbon, polystyrenedivinylbenzene copolymer, or molecularly imprinted polymers, can be used. This technique has been used to extract a wide range of analytes including drugs from biological samples [31][32][33][34], polycyclic aromatic hydrocarbons, and semi-volatile residues in water [35,36], analysis of small brominated and chlorinated aromatic compounds in wine [37], flavonoid content in fruit juice [38], phenolic anti-oxidants from cereal products [39], and environment pollutants [40].…”
mentioning
confidence: 99%
“…Any sorbent material such as silica-based (C2, C8, C18), strong cation exchanger (SCX) using sulfonic acid-bonded silica, restricted access material, HILIC, carbon, polystyrenedivinylbenzene copolymer, or molecularly imprinted polymers, can be used. This technique has been used to extract a wide range of analytes including drugs from biological samples [31][32][33][34], polycyclic aromatic hydrocarbons, and semi-volatile residues in water [35,36], analysis of small brominated and chlorinated aromatic compounds in wine [37], flavonoid content in fruit juice [38], phenolic anti-oxidants from cereal products [39], and environment pollutants [40].…”
mentioning
confidence: 99%
“…Microextraction in a packed syringe (MEPS) is a rather new technique used for the extraction and preconcentration of trace amounts of analytes into a solid support sorbent packed inside two frits in a syringe or microsyringe. [12][13][14] In this technique, sample preparation takes place on a packed bed of the sorbent. The sorbent is inserted in the barrel of a 1-mL insulin syringe as a plug with two polyethylene filters on both sides.…”
Section: Introductionmentioning
confidence: 99%
“…Most of the proposed analytical methods for determination of mepivacaine are based on separation techniques such as liquid chromatography, 3,5-9 gas chromatography [10][11][12][13][14] and electrophoresis. [15][16] Furthermore, an electrochemical method has been proposed for determination of mepivacaine.…”
Section: Introductionmentioning
confidence: 99%