2018
DOI: 10.3390/en11040984
|View full text |Cite
|
Sign up to set email alerts
|

New Switched-Dual-Source Multilevel Inverter for Symmetrical and Asymmetrical Operation

Abstract: Abstract:The increasing integration of large solar PV and wind farms into the power grid has fueled, over the past two decades, growing demands for high-power, high-voltage, utility-scale inverters. Multilevel inverters have emerged as the industry's choice for megawatt-range inverters because of their reduced voltage stress, capability for generating an almost-sinusoidal voltage, built-in redundancy and other benefits. This paper presents a novel switched-source multilevel inverter (SS MLI) architecture. This… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
7
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 24 publications
(51 reference statements)
0
7
0
Order By: Relevance
“…A new switched source MLI is proposed which operates under both symmetric Electronics 2021, 10, 368 2 of 23 and asymmetric mode. The proposed inverter is designed with six power switches and two voltage sources [9]. A new 81-level MLI is presented using two stage ladder circuits and the values of the dc sources are fixed by two different algorithms.…”
Section: Introductionmentioning
confidence: 99%
“…A new switched source MLI is proposed which operates under both symmetric Electronics 2021, 10, 368 2 of 23 and asymmetric mode. The proposed inverter is designed with six power switches and two voltage sources [9]. A new 81-level MLI is presented using two stage ladder circuits and the values of the dc sources are fixed by two different algorithms.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, the requirement of filters reduces due to the inverter. Additionally, MLI provides extra advantages like enhanced efficiency, reduced the stress of dv/dt, lesser electromagnetic interference [12][13][14][15][16]. Among all the topologies for high power applications, the multilevel inverter is preferred [17].…”
Section: Introductionmentioning
confidence: 99%
“…In [24], the authors developed an H-bridge to generate a 5 level and 25 level inverter using symmetrical and asymmetrical voltage sources, respectively. In [25,26], working of asymmetric type MLI operations were presented.…”
Section: Introductionmentioning
confidence: 99%