2010
DOI: 10.1007/s10967-010-0574-9
|View full text |Cite
|
Sign up to set email alerts
|

New SRDN-3 probes with a semi-conductor detector for measuring radon activity concentration in underground spaces

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
9
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 16 publications
(13 citation statements)
references
References 61 publications
0
9
0
Order By: Relevance
“…with its radioactive daughters, is responsible for about 40−50% of (1 -2.5 mSv/year) which a typical person receives from all natural sources of ionising radiation within a year (Commission 1990;UNSCEAR, 2000;Waligórski, 2010 Przylibski and Fijałkowska-Lichwa, 2010;Gillmore et al, 2001Gillmore et al, , 2002Chibowski and Komosa, 2001;Kullab et al, 2001;Kávási et al, 2003;Papachristodoulou et al, 2004;Perrier et al, 2004a, b;Olszewski et al, 2005;Lario et al, 2005Lario et al, , 2006Gervino et al, 2007;Lu et al, 2009;. Their findings have turned out to be comparable, and the most recent studies only extend the previously known regularities to next underground spaces.…”
mentioning
confidence: 99%
“…with its radioactive daughters, is responsible for about 40−50% of (1 -2.5 mSv/year) which a typical person receives from all natural sources of ionising radiation within a year (Commission 1990;UNSCEAR, 2000;Waligórski, 2010 Przylibski and Fijałkowska-Lichwa, 2010;Gillmore et al, 2001Gillmore et al, , 2002Chibowski and Komosa, 2001;Kullab et al, 2001;Kávási et al, 2003;Papachristodoulou et al, 2004;Perrier et al, 2004a, b;Olszewski et al, 2005;Lario et al, 2005Lario et al, , 2006Gervino et al, 2007;Lu et al, 2009;. Their findings have turned out to be comparable, and the most recent studies only extend the previously known regularities to next underground spaces.…”
mentioning
confidence: 99%
“…Such a powering method enables unmanned measurement regime over a period of at least one year with a possibility of recording the measured parameters ( 222 Rn activity concentration, temperature, and relative humidity) with 60-min data recording frequency. The lower detection limits of SRDN À3 probes for a 60-min data recording mode, the maximum measurable 222 Rn activity concentration and the calibration coefficient are about 90 Bq m -3 , about 157 MBq m -3 and about 35-45 Bq/m 3 /imp./h respectively, depending on the specimen of the probe (Przylibski et al, 2010).…”
Section: Rn Activity Concentration Measurement Methodsmentioning
confidence: 92%
“…A detailed description of 222 Rn activity concentration measurement method using SRDN-3 probes was included in reports by Przylibski et al (2010) and by Fijałkowska-Lichwa and Przylibski (2011).…”
Section: Rn Activity Concentration Measurement Methodsmentioning
confidence: 99%
“…The probes are Polishmade devices equipped with semiconductor detectors frequently used in long-term measurements conducted in underground spaces [21,22,84,85] including the tunnels under the cour d'honneur of Książ castle [24,71]. The construction and the operation principle of the SRDN-3 probe have been repeatedly discussed in publications, and its detailed description was included in the work by Przylibski and co-authors [84]. The 222 Rn activity concentration detection thresholds for SRDN-3 probes range The semiconductor SRDN-3 detectors were positioned on tripods at the height of 1 m over the floor of each corridor ( Fig.…”
Section: Radon Measurementsmentioning
confidence: 99%
“…The measurement uncertainty depends on the size of the measured 222 Rn activity concentration and it may range from 21 to 39%. The higher the value of 222 Rn activity concentration, the lower the measurement concentration, starting from 20% for 222 Rn values of the order of 1000 Bq/m 3 to even 7% for the value in the range of 5000-10,000 Bq/m 3[23,84].…”
mentioning
confidence: 99%