2021
DOI: 10.1107/s1600576721002235
|View full text |Cite
|
Sign up to set email alerts
|

New sample stage for characterizing radioactive materials by X-ray powder diffraction: application on five actinide dioxides ThO2, UO2, NpO2, PuO2 and AmO2

Abstract: A new sample stage for characterizing radioactive materials by X-ray powder diffraction was developed at the ATALANTE facility (CEA Marcoule, France) using a conventional (non-nuclearized) Bruker D8 goniometer mounted in Bragg–Brentano geometry. The setup consists of a removable, fully hermetic sample stage, with a 200 µm-thick beryllium window, that can be plugged onto a glove-box, allowing the sample to be introduced in an hermetic medium that also encapsulates the glove-box atmosphere throughout the analysi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 60 publications
(56 reference statements)
0
5
0
Order By: Relevance
“…The mixture was spread onto a Si low background sample holder, and covered by a hermetic fully removable sample dome, compatible with a Bruker D8 goniometer installed in a glovebox. 52…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The mixture was spread onto a Si low background sample holder, and covered by a hermetic fully removable sample dome, compatible with a Bruker D8 goniometer installed in a glovebox. 52…”
Section: Methodsmentioning
confidence: 99%
“…For Pu containing samples, the powder is mixed with 30 mg of silicone grease for particle immobilization. The mixture is spread onto a Si low background sample holder, covered by an hermetic fully removable sample dome, compatible with Bruker D8 goniometer installed in a glovebox [52].…”
Section: Powder X-ray Diffractionmentioning
confidence: 99%
See 1 more Smart Citation
“…The mixture was then dispersed in a polymer grease in order to avoid spreading powder. Further details can be found in Vauchy et al [VAU21]. The diffraction patterns were collected by scanning from 20° to 140° 2θ with a set-interval of 0.1° 2θ and a counting time of 5 seconds per step.…”
Section: Xrdmentioning
confidence: 99%
“…Different approaches have been used to fulfill those requirements. In some laboratories, the whole diffractometer is inside a glove box, where the sample preparation and measurement are carried out under nitrogen atmosphere (Belin et al, 2015), others developed a sample stage dedicated for irradiated samples (Vauchy et al, 2021). Inspired by holders for air-sensitive samples (Ritter, 1988;Rink et al, 1994;Rodriguez et al, 2008), other authors designed a holder to enclose the sample avoiding the powder exchange with the external atmosphere.…”
Section: Introductionmentioning
confidence: 99%